1 © 2013 IBM Corporation Follow us @IBMpowersystems@IBMpowersystems Learn more at www.ibm.com/powerwww.ibm.com/power This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients IBM Power Systems AM71/AS600 Technical Sales Common Skills Unidade 5 – Power Express Servers

2 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 2 Objetivos da Unidade Ao final desta unidade, você será capaz de:  Descrever as vantagens dos servidores Power Systems e relatar produtos aos clientes  Identificar e posicionar o alvo desejado com servidores IBM POWER7 Express

3 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 3 Quanto é necessário conhecer sobre estes produtos?  Depende do seu trabalho  Depende dos seus clientes “A gama de produtos está mudando, como se atualizar?”  Fatos e features  Cartas de anúncios  Redbooks  Este curso

4 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 4 Produtos e Tecnologia  Produtos podem estar além dos pacotes tecnológicos  Nós temos passado algum tempo aprendendo tecnologia  Se houver alguma compreensão sobre tecnologia, será mais fácil lidar com produtos

5 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 5 POWER7+ 770 POWER7+ 780 Power 775 Power 755 POWER7+ 750 / 760 POWER7+ 710/730 POWER7+ 720/740 PS Blades Power 795 IBM PureFlex System PowerLinux 7R1 / 7R2 /7R4 p460 p260+ p24L Portifólio POWER7 Express servers

6 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 6 Família Entry Power Systems Power 710, 730, 720, 740, 750, 7R1, 7R2 ‘D’ modelos com aprimoramento de capacidades  Mais alta perfomance com POWER7+ –Frequência de processador aumentada em 20% –2.5x de memória cache L3 –Hardwares de aceleração integrados Expansão de Memória (AME) Criptografia  Dobro da capacidade de memória –Novas 16, 32, e 64 GB features de memória  Capacidade de disco interno aumentada com discos de 900GB  5.4 TB para Power 710 e 730 –7.2 TB para Power 720 e Power 740 –5.4 TB para Power 750  Até 20 partições/core com PowerVM  Economia de energia via melhorias de processadores

7 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 7 POWER7+ Oferecem melhores preços e performance Baseados em rPerf e preços USA  Power 740: 21-42% melhor  Power 720: 14-21% melhor  Power 730: 49-60% melhor  Power 710: 16-39% melhor

8 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 8 POWER7+ 710 and 730 POWER7+ 710: 1S2U POWER7+ 730: 2S2U Power 710 8231-E1D Power 730 8231-E2D Arquitetura POWER7+ 4 Core @ 3.6 GHz 6 Core @ 4.2 GHz 8 Core @ 4.2 GHz 8 Core @ 4.3 GHz 12 Core @ 4.2 GHz 16 Core @ 3.6 GHz 16 Core @ 4.2 GHz PlanarSingle SocketDual Socket DDR3 Memory 4 / 8 / 16 / 32 GB DIMMs 8GB to 256GB 4 / 8 / 16 / 32 GB DIMMs 8GB to 512GB SFF SAS BaysUp to 6 HDD or SSD PCIe Gen2 Expansion Slots Five 8x Low Profile (LP) One 4x LP (Ethernet Quad 10/100/1000 ) Integrated SAS/SATA Controller Standard: RAID 0, 1, & 10 Optional: RAID 5 & 6 GX++ Slots One (n/a with 4-core feature) Two Media Bays1 Slim-line & optionally 1 Half Height 12X PCIe Drawers *NoMax = 2 EXP24S Drawer *Max = 4Max = 14 Ultra SSD Drawer *Max = 1/2Max = 1 Redundant Power & Cooling OptionalStandard Warranty3 Years Power 730 Suporta até 320 LPARs Power 710 Suporta até 160 LPARs

9 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 9 Power 710/730 - Rack-mount  710 / 730 –Bezel feature code, vem com servidor –Feature code dos trilhos, vem com servidor  Apenas Rack-mount --- sem opção de torre Note: Os trilhos são ajustáveis na profundidade de 28” à 32” Os mesmos trilhos são usados pela 720/740, porém, usando diferentes locais de anexo e enviado com diferentes acessórios comparado a 720/740. Mínima diferença de profundidade pois a 710/730 tem maior profundidade que a 720/740. No features to order

10 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 10 Power 710/730 (8231-E1D/E2D) Memory Riser Cards Min qtd risers Max qtd risers Max qtd opcional 710: 4-/6-/8-core121 730: 8-/12-/16-core143 1-4 cards per 730 1-2 cards per 710 4 Memory DIMM slots Memory riser card or Memory card New #5265 feat code

11 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 11 POWER7+ 710 Memory DIMMs (8231-E1D)  DDR3 1066 MHz DIMMs  4 DIMM slots por memory riser card, podendo chegar até 8 DIMM slots para 710  DIMM size: 4, 8, 16, 32 GB (2 por feature code)  DIMMs instalados em pares  Mix de até dois DIMMs no mesmo riser. Riser cards diferentes podem possuir diferentes tamanhos de DIMMs. GB Capacidade de Memória com * DIMM size1 Pair 2 Pair 1 Quad 3 Pair 4 Pair 2 Quad All 4 GB8162432 All 8 GB16324864 All 16 GB326496128 All 32 GB64128192256 ½ 8GB + ½ 16 GB24487296 Feature Code Feature GB #EM088 #EM4B16 #EM4C32 #EM4D64 1 riser card2 riser cards *Subconjunto de configurações em GB mostrada na tabela

12 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 12 POWER7+ 730 Memory DIMMs (8231-E2D)  DDR3 1066 MHz DIMMs  4 DIMM slots por riser card, chegando à 16 DIMM slots na 730  DIMMS: 4, 8, 16, or 32 GB (2 por feature code)  DIMMs instalados em pares.  Mix de até 2 tamanhos de DIMMs no mesmo riser. Diferentes riser cards podem possuir diferentes tamanhos de DIMMs. GB Capacidade de memória com* DIMM size1 Pair* 2 Pair 1 Quad 3 Pair 4 Pair 2 Quad 5 Pair 6 Pair 3 Quad 7 Pair 8 Pair 4 Quad 4 GB8*16243240485664 8 GB163248648096112128 16 GB326496128160192224256 32 GB64128192256320384448512 ½ 8GB + ½ 16 GB 24487296120144168192 1 riser card2 riser cards Feature Code Feature GB #EM088 #EM4B16 #EM4C32 #EM4D64 3 riser cards4 riser cards *Subconjunto de configurações em GB mostrada na tabela

13 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 13 Power 710/730 (8231-E1D/E2D) PCI Slots GX++ Slot 1 PCIe Gen2 Slots x8 12345 PCIe x4 slot for LAN adapter GX++ Slot 2 Compartilha espaço com C7 slot 5 Low profile x8 Gen2 slots para uso geral Mais 1 Low profile Gen2 x4 slot para # 5260 LAN adapter No IVE/HEA Nota: 710/730, PCIe Gen2 slots não são hot plug “ C7 ”

14 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 14 710/730 Opções de Storage Backplane (“Modelos C/D”) Necessária uma seleção  6 SAS bays - DVD bay 3 SAS bays - HH Media bay DVD bay 6 SAS bays Cache*/RAID SAS port - DVD bay #EJ0D AIX / Linux supportyes IBM i supportno/yes** yes JBODyes no RAID 0yes RAID 5/6no yes RAID 10yes Split backplaneno USA list price$ 799$ 836$1800 * Dual 175MB write cache adds RAID-5/6 & add’l performance ** supported only through VIOS #EJ0E #EJ0F Preço de entrada, Função de entrada Prices are USA suggested list prices as of Oct 2012. Prices are subject to change without notice. Reseller prices may vary.

15 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 15 710/730 Backplane com 3 SAS SFF Bays + HH Bay  Two HH Media Bay Options* –80/160GB Unidade de fita DAT160 (#1124) Drive pequeno para 710/730 Utiliza cartuchos DAT72 ou DAT160 –Removable Disk Drive (RDX) - USB (#EU23) Drive pequeno para 710/730 Utiliza drives 160GB, 320GB, 500GB, 1TB or 1.5TB RDX (#1106/EU08/1107/EU01/EU15) –Nenhuma unidade LTO, DAT72 ou DAT320 driven as 710/730 CEC – use external  3 SFF SAS Bays executando através de controladores SAS (zero cache para gravação) –Para HDD ou SSD –JBOD, RAID 0 e 10 pela controladora embutida ou espelhado pelo sistema operacional. 3 SFF SAS bays HH media bay DVD-RAM (#5771) #EJ0E *Note: List reflects Media Bay options that are orderable. Consult the sales manual for complete list of Media Bay features that are supported.

16 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 16 710/730 Backplane com 6 SAS SFF Bays 6 SFF SAS bays DVD-RAM #EJ0D/EJ0F  DVD RAM (#5771)  6 SFF SAS Bays executado pela controladora SAS integrada –Pelo HDD ou SSD –Sem split backplane –With #EJ0D (função de entrada, sem cache, sem RAID-5/6/10) JBOD, RAID 0 and 10 pela controladora embutida, ou por espelhamento via sistema operacional –With #EJ0F (funcionalidade superior, cache de gravação dupla, porta RAID e SAS) RAID 0, 5, 6, 10 ou espelhados via sistema operacional

17 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 17 710/730 Adaptador GX++  #EJ0H GX++ LP 1-port PCIe2 x8 Adapter on Power 710/730 - Attach #EDR1 EXP30 Ultra SSD I/O Drawer  #EJ0G GX++ Dual-port 12x Channel Adapter on Power 730 - Attach Remote I/O Drawer Expansion  Sem loops 12X I/O disponíveis na Power 710 Vista Trazeira 730 1 st GX slot 710 or 730 2 nd GX slot 730

18 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 18 710/730 Conectando a 4X IB Switches  Power 710/730 (8231-E1D/E2D): –Usa adaptadores QDR #5283 na Gen2 PCIe slot  Power 710/730 (8231-E1C/E2C): –Usa adaptadores QDR #5283 na Gen2 PCIe slot  Power 710/730 (8231-E2B) –Usa #5266 GX++ Dual-port 4x Channel Attach in GX++ slot (DDR) Sem suporte a IBM i

19 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 19 710/730 (#5260) Adaptador LAN / C7 Slot  4-Port LAN Adapter (1 requerida por modelo “D” 710/730) –#5260 PCIe2 LP 4-port 1Gb Ethernet Adapter –Low profile para Power 710/730 –Portas TX para par trançado sem blindagem (UTP) de cobre  C7 Slot –Em 8231-E1D/E2D –Tecnicamente é um slot x4 PCIe Gen2 slot rotulado “C7”. Possui largura de banda de uma 8x Gen1 slot. Unicamente o #5260 LAN adapter são suportados nesse slot. 730 nota: Se o GX++ adapter for plugado, o C7 slot será coberto. Deve-se então, mover o adaptador para outro lugar.  Virtualização –A virtualização dessas portas querer o uso de VIOS ou IBM i –IVE/HEA podem virtualizar sem VIOS ou IBM i, se desejado –IBM i pode virtualizar para outro IBM i LPARs (Use VPM se precisar evitar HMC)

20 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 20 Power 730 (8231-E2D) GX++ Adaptadores de Expansão  #EJ0G GX++ Dual-port 12x Attach  Aadaptador 12X PLUS 2 nd adaptador SPCN (Ambos enviados como feature code #EJ0G)  Adaptador Double wide –Utiliza GX++ Slot 2 e cobre ambos PCIe LAN slot C7 e outro PCIe slot –Adaptador SPCN Plus utiliza GX++ Slot 1 –Obrigatoriamente #9056 adaptador LAN precisa ser movido para outro PCIe slot no servidor.  20 GB Máxima Largura de banda  Fornece um loop 12X e suporta acima de duas PCIe 12X IO Drawers –#5802 e/ou #5877 PCIe I/O drawers –PCI-X #5796 gavetas não são suportadas Cartão Double-wide (SPCN card não mostrado) 730 (8231-E2B) não possuia capacidade de loop 12x

21 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 21 Power 730 IO Loop / Drawer option Model E2C/E2D #5802 or #5877  Single 12X Loop –Requer FC #EJ0G  Suporte para até duas PCIe 12X IO Drawers –#5802 e/ou FC # 5877 –#5796 PCI-X 12X I/O drawer Não suportado  Total I/O Adapter Slots: 24 – 4 internos LP PCIe Gen2 slots / ( Ethernet Adapter ) – Até 20 externos PCIe Gen1 slots

22 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 22  Robusta e confiável –1 ou 2 sockets, 2U rack mount –Até 8, POWER7+ cores por socket –256 GB memória por socket, 512 GB max.  Escalável e eficiente com PowerVM –Mais cargas e throughput por servidor –Até 20 VMs por core (320 VMs total)  Desempenho inigualável entregando maior economia –Custo até 41% menor com a solução virtualizada –Preço comparável ao x86 Linux (Servidor, virtualização software e SO Linux) Virtualization & Mgmt. Linux-only POWER7+ Operating Systems PowerLinux 7R1 1 socket: 4-core @ 3.6 GHz 1 socket: 6 or 8-core @ 4.2 GHz PowerLinux 7R2 2 sockets: 8-core @ 3.6 GHz 2 sockets: 8-core @ 4.2 GHz IBM PowerLinux 7R1 / 7R2 Ideal para múltiplas cargas de Linux

23 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 23 PowerLinux 7R1 / Power 710 Posicinamento PowerLinux 7R1Power 710 8246-L1T8246-L1D8231-E1D Operating Systems POWER7+ Architecture One Socket 4 Core @ 3.6 GHz 6 Core @ 4.2 GHz 8 Core @ 4.2 GHz 4 Core @ 3.6 GHz 6 Core @ 4.2 GHz 8 Core @ 4.2 GHz DDR3 Memory 4 / 8 / 16 / 32 GB DIMMs 32GB to 256B 4 / 8 / 16 / 32 GB DIMMs 8GB to 256GB 12X PCIe Expansion DrawerN/A HDD/SSD storage drawersUp to 4N/AUp to 4 EXP30 Ultra SSD DrawerN/A Up to ½ SAS SFF BaysUp to 6 HDD or SSD PCIe Gen2 SlotsGeneral Purpose: Five x8 LP & Dedicated: One x4 LP (Ethernet Adapter) Integrated SAS/SATA CntrlStandard: RAID 0, 1, & 10 Optional: RAID 5 & 6 GX++ SlotsOne Integrated Ports3 USB, 2 Serial, 2 HMC Ethernet in 6 th PCIe slotQuad Port 10/100/1000 Media Bays1 Slim-line (DVD) & optionally 1 Half Height ( DAT 160/320 tape or RDX ) Virt ManagementIVM or HMC Redundant Power & CoolingStandard Warranty3 Years

24 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 24 PowerLinux 7R2 / Power 730 Posicionamento PowerLinux 7R2Power 730 8246-L2T8246-L2D8231-E2D Operating Systems POWER7+ Architecture Two Sockets 16 Cores @ 3.6 GHz 16 Cores @ 4.2 GHz 8 Cores @ 4.3 GHz 12 Core @ 4.2 GHz 16 Core @ 3.6 / 4.2 GHz DDR3 Memory 4 / 8 / 16 / 32 GB DIMMs 32GB to 512GB 4 / 8 / 16 / 32 GB DIMMs 8GB to 512GB 12X PCIe Expansion DrawerUp to 2N/AUp to 2 HDD/SSD storage drawersUp to 14N/AUp to 14 EXP30 Ultra SSD DrawerUp to 1N/AUp to 1 SAS SFF BaysUp to 6 HDD or SSD PCIe Gen2 SlotsGeneral Purpose: Five x8 LP & Dedicated: One x4 LP (Ethernet Adapter) Integrated SAS/SATA CntrlStandard: RAID 0, 1, & 10 Optional: RAID 5 & 6 GX++ SlotsTwo Integrated Ports3 USB, 2 Serial, 2 HMC Ethernet in 6 th PCIe slotQuad Port 10/100/1000 Media Bays1 Slim-line (DVD) & optionally Half Height ( DAT 160/320 tape or RDX ) Virt ManagementIVM or HMC Redundant Power & CoolingStandard Warranty3 Years

25 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 25 POWER7+ 720 / 740 * Power 720 8202-E4D Power 740 8205-E6D POWER7+ Architecture 4-core 3.6 GHz 6-core 3.6 GHz 8 core 3.6 GHz 6 or 12-core 4.2 GHz 8 or 16-core 3.6 GHz 8 or 16-core 4.2 GHz PlanarSingle SocketSingle or Dual Socket DDR3 Memory DIMMs 4 / 8 / 16* / 32* GB 4GB to 512* GB 4 / 8 / 16 / 32 GB 4GB to 1 TB SAS SFF BaysUp to 6 or 8 HDD or SSD PCIe Gen2 Expansion Slots Five 8x Full High (FH) One 4x FH Ethernet (Quad 10/100/1000) Four 8x LP ( Optional) Integrated SAS Controller Standard: RAID 0, 1, & 10 Optional: RAID 5 & 6 GX++ Slots One (n/a with 4-core feature) Two Media Bays1 Slim-line & 1 Half Height I2X PCIe IO Drawers Max 2 **Max 4 12X PCI-X I/O Drawers 48 EXP24S DrawerMax 14**Max 14 Ultra SSD DrawerMax 1 **Max 2 Redundant Power and Cooling OptionalStandard Warranty3 Years Power 720: 1S4U Power 740: 2S4U Power 720: 1S4U Tower

26 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 26 Power 720 (8202-E4D) – Pedido Torre ou Rack-mount Notes: Os trilhos são ajustáveis até a profundidade de 21” à 32” O conjunto de capas da Torre inclui um bloqueio de chave de segurança para capa – sem tampa traseira oferecida Características do cabo de aliementação são diferentes entre torre e Rack – rack usa 200-24V PDU Pode adicionar/remover recursos por pedido de MES. CSU designado, mas recomneda-se pessoal familiarizado. Preços totais para recursos adicionados. 720 Tower #7567 IBM Tower Cover Set 720 #7134 IBM Rack-mount Drawer Bezel e Hardware para ambas IBM e não IBM racks Rails são profundidade ajustável de cerca de 21 "a 32" Torre conjunto de capa inclui um bloqueio de chave de segurança para capa - sem tampa traseira oferecido Características do cabo de alimentação são diferentes entre torre e Rack - rack de usa 200-24V PDU

27 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 27 Power 740 (8205-E6D) – Apenas Rack-mount Notas: Os trilhos são ajustáveis até a profundidade de 21” à 32” Assim como 740(8205-E6B) exceto pela falta de opção de torre 8205- E6C/E6D 740 #7131 IBM Rack-mount Drawer Bezel e Hardware para ambas IBM e racks não IBM

28 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 28 Power 720/740 – Memory Riser Cards Memory riser card or Memory card 8 DIMM slots Qtd min risers Qtd Máx risers Qtd Máx opcional 720: 4-/6-/8-core 1 x #EPCK/#EPCL#EPCM 121 740: 6-/8-core 1 x #EPCP/#EPCQ/#EPCR 121 740: 12-/16-core Need 2 proc modules for max #EM01 2 x #EPCP/#EPCQ/#EPCR 143 8 Memory DIMM slots 1-4 cards per 740 1-2 cards per 720

29 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 29 Power 720 Memory DIMMs (8202-E4D)  DDR3 1066 MHz DIMMs  Até 16 slots DIMM por 720  DIMMS: 4, 8, 16**, ou 32** GB (2 DIMMs por feature code)  DIMMs instalados em pares  Mesmo tamanho de DIMMs num set de 4 DIMM slots (quad). Não necessita preencher o quad antes de colocar outro par em outro quad.  Mixa diferentes tamanhos de DIMMs no mesmo riser. Os riser cards podem possuir diferentes tamanhos de DIMMs. GB Capacidade de Memória com (Possíveis configs) DIMM size1 Pair** 2 Pair 1 Quad 3 Pair 4 Pair 2 Quad 5 Pair 6 Pair 3 Quad 7 Pair 8 Pair 4 Quad All 4 GB816243240485664 All 8 GB163248648096112128 All 16 GB *326496128160192224256 All 32 GB *64128192256320384448512 Mix ½ 8 GB + ½ 16 GB 16 or 324864 or 8096 112 or 128 144 160 or 176 192 1 riser card 2 riser cards * EM4C / EM4D features não são suportados com 4-core Power 720 ** Suporta apenas um par em entry-level Feature Code Feature GB #EM088 #EM4B16 #EM4C *32 #EM4D *64

30 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 30 Power 740 Memory DIMMs (8205-E6D)  DDR3 1066 MHz DIMMs  Até 32 DIMM slots por 740  DIMMS: 4, 8, 16, or 32 GB (2 DIMMs por feature)  DIMMs instaladas em pares  Mesmo tamanho de DIMMs num set de 4 DIMM slots (quad).  Não necessita preencher o quad antes de colocar outro par em outro quad.  Mixa diferentes tamanhos de DIMMs no mesmo riser. Os riser cards podem ter diferentes tamanhos de DIMMs. GB Capacidade de Memória com (Possíveis configs) DIMM size 2 Pair 1 Quad 4 Pair 2 Quad 6 Pair 3 Quad 8 Pair 4 Quad 10 Pair 5 Quad 12 Pair 6 Quad 14 Pair 7 Quad 16 Pair 8 Quad All 4 GB 163248648096112128 All 8 GB 326496128160192224256 All 16 GB 64128192256320384448512 All 32 GB 1282561925126407688961024 Mix ½ 8 GB + ½ 16 GB 4896144192240288336384 1 riser card 2 riser cards 3 riser card 4 riser cards Feature Code Feature GB #EM088 #EM4B16 #EM4C32 #EM4D64

31 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 31 710/720/730/740 Considerações de Performance de Memória  Nota - palavra “depende” sempre sempre começam cada ou regra de discução e aqui também se faz assim.  Regras Gerais: –Para futuro crescimento, deixa algum slot de memória DIMM vazio –Mais DIMMs de memória, mais largura de banda de memória. Máxima largura de banda é conseguida com todos os slots de DIMMs preenchidos com a máxima quantidade de riser cars de memória. Nota – para aplicações comerciais em servidores com níveis de utilização típica, a performance incremental ganhou pelo número máximo de DIMMs. Um subconjunto diz que 50% de DIMMs tem a utilização muito modesta. Note que partindo de 2 DIMMs à 4 DIMMs duplica-se a largura de banda. Geralmente é recomendado pelo menos 4 DIMMs (2 features e 1 quad) para cada riser, a menos que seja bem pouca carga. Com múltiplos risers, conseguimos um melhor balanço de memória Balanco de GB total por riser antes balanceando o número de DIMMs por riser Nota – para aplicações comerciais em servidores com níveis de utilização típica, diferenças de 2X entre o maior e o menor GB riser são de menores impacto de performance. –Com dois servidores de socket (730/740) são espalhadas memórias entre os sockets Propondo ter pelo menos 2 risers, então pelo menos 1 riser associado a cada socket e cada riser contendo pelo menos 1 quad de memória DIMMs, a menos que se tenha um baixo carregamento.  Observações: –Adicionando memória obrigatória para que o sistema seja desligado –Active Memory Expansion pode eficientemente expandir capacidade de memória para AIX 6.1 e para para inúmeros ambientes de aplicação –Todo riser card necessita ter pelo menos 1 par de DIMMs

32 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 32 Power 720/740 (8202-E4D/8205-E6D) PCI Slots X8 PCIe Gen2 Slots 12345 PCIe x4 slot for LAN adapter GX++ Slot 1 GX++ Slot 2 Compartilhe espaço com LAN slot No IVE/HEA Opt PCIe Riser Card PCIe Gen2 Slots 1234 5 full high x8 Gen2 slots para uso geral Mais 1 Low profile Gen2 x4 slot for #5899 LAN adapter Mais 4 opcionais x8 low profile Gen2 slots Nota: 720/740, PCIe Gen2 slots não são hot plug “ C7 ”

33 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 33 PCIe Gen2 for Power 720/740 Express  Opcional PCIe Riser Card é plugado no primeiro GX slot da 720/740 PCIe riser card 4 LP Gen2 PCIe slots #5685 Usado em toda 720/740 Newer Gen2 720/740 usa apenas Gen2 PCIe Riser Card Gen2 riser card suporta todo LP Gen1 card mais Gen2 cards.

34 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 34 720/740 (#5899) LAN Adapter / C7 Slot  4-Port LAN Adapter (1 obrigatória por modelo “D” 720/740) –#5899 PCIe2 4-port 1Gb Ethernet Adapter Adaptador Full high para Power 720/740 –Portas TX são ports para Unshielded Twisted Pair (UTP) cobreado  C7 SLOT –Nas 8202-E4D/8205-E6D –Tecnicamente é um slot x4 PCIe Gen2 slot nomeado “C7”. Ele possui uma largura de banda de um 8x Gen1 slot. –Unicamente #5899 LAN adapter é suportado neste slot. 740 nota: se o adaptador GX++ for conectado, o slot C7 será coberto. Será necessário movê-lo para outro lugar.  Virtualização –Virtualizar essas portas requer VIOS ou IBM i Com as portas IVE/HEA podemos virtualizar sem o VIOS ou IBM I, se desejado –IBM i pode virtualizar para outras LPARs de IBM i (usando se necessário VPM, sem a necessidade de HMC)

35 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 35 720/740 Opções Storage Backplane (Modelos “C/D”) Must select one  6 SAS bays - HH media bay DVD bay 8 SAS bays Cache*/RAID SAS port HH Media bay DVD bay #5618 AIX / Linux supportyes IBM i supportno/yes** yes JBODyes no RAID 0yes RAID 10yesyes***yes RAID 5/6no yes Split backplanenoyesno USA list price $799$799+799$1800 #EJ01 Valor Entry, Função Entry 3+3 SAS bays - HH media bay DVD bay #5618+EJ02 Prices are USA suggested list prices as of Oct 2012. Prices are subject to change without notice. Reseller prices may vary. *Cache de gravação 175MB dupla acrescenta RAID-5/6 e desempenho adicional ** Suportado apenas através VIOS *** RAID 10 em ambos os conjuntos de três (modelos E4B/E6B tem RAID10 com conjunto)

36 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 36 720/740 Media Bays HH media bay DVD-RAM (#5771) #5618 6 SFF SAS bays  Opções* de HH Media Bay –Disk Drive Removível (RDX) - USB (#EU03) –Disk Drive Removível (RDX) - SATA (#EU07) –80/160GB DAT160 Tape drive - USB (#EU16) –80/160GB DAT160 Tape drive - SAS (#5619) –1.5TB/3TB LTO5 tape drive - SAS (#5638) –2.5TB/6TB LTO6 tape drive - SAS (#EU11)  6 SFF SAS Bays executando via controladora SAS integrada –Para HDD ou SSD –JBOD, RAID 0/10 por controladora integrada, ou espelhado por sistema operacional –Sem split backplane –Sem suporte a IBM i * Nota: Lista reflete as opções de mídias que são pedidas. Consulte o manual de vendas para a lista completa de recursos de mídias que são suportados.

37 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 37  Opções* HH Media Bay –Disk Drive Removível (RDX) - USB (#EU03) –Disk Drive Removível (RDX) - SATA (#EU07) –80/160GB DAT160 Tape drive - USB (#EU16) –80/160GB DAT160 Tape drive - SAS (#5619) –1.5TB/3TB LTO5 tape drive - SAS (#5638) –2.5TB/6TB LTO6 tape drive - SAS (#EU11)  SFF SAS Bays executado via controladoras SAS integradas –Para HDD or SSD em qualquer “split”, sem mix em um “split” –JBOD, RAID 0/10 via controladora integrada, ou espelhada pelo sistema opercaional –Split backplane –Sem suporte a IBM i 720/740 Media Bays HH media bay DVD-RAM (#5771) #5618 + #EJ02 3 x 3 SFF SAS bays * Nota: Lista reflete as opções de mídias que são pedidas. Consulte o manual de vendas para a lista completa de recursos de mídias que são suportados.

38 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 38 720/740 Backplane com 8 SAS SFF Bays 8 SFF SAS bays HH media bay DVD-RAM (#5771) #EJ01 SAS port For #5886 EXP12S or #5887 EXP24S Disk Drawer  HH Media Bay Options* –Disk Drive Removível (RDX) - USB (#EU03) –Disk Drive Removível (RDX) - SATA (#EU07) –80/160GB DAT160 Tape drive - USB (#EU16) –80/160GB DAT160 Tape drive - SAS (#5619) –1.5TB/3TB LTO5 tape drive - SAS (#5638) –2.5TB/6TB LTO6 tape drive - SAS (#EU11)  8 SFF SAS Bays executadas via dupla controladora SAS integrada (175MB duplo cache de gravação) –For HDD or SSD –RAID 0/5/6/10 by imbedded controller, or mirrored by operating system –External SAS port –No split backplane * Nota: Lista reflete as opções de mídias que são pedidas. Consulte o manual de vendas para a lista completa de recursos de mídias que são suportados.

39 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 39 Power 520 para Power 720 Upgrades De POWER6 para POWER7 preservando o número de série POWER6 720 6/8-core Modelo “B” POWER7 8202-E4B 720 6/8-core Modelo “C” 720 6/8-core Modelo “D” POWER7+ 8202-E4D POWER7 8202-E4C withdrawn 520 4-core 8203-E4A 520 2-core 8203-E4A Notas:  Sem upgrades oferecidos para Power 720, 4 cores  Sem upgrades oferecidos para Power 520, 1-core  Upgrade de Power 720 modelo E4B para E4C para E4D não são oferecidos  As conversões dePOWER6 9408-M25 para POWER6 8203-E4A continuam disponíveis 520 1-core 8203-E4A 720 4-core

40 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 40 Mixando Power 770 & Power 740 = Power 750/760 Quad Sockets IO Subsystem Arquitetura de Memória RAS Features Power 740 Power 770 Power 760 Power 750 Enterprise System features Express System pricing

41 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 41 Power 750 Supports up to 640 LPARs Até 32 Cores 4 Socket / 5U Power 750 8408-E8D POWER7+ Arch. Up to 4 Sockets 8-core DCM @ 4.0 GHz 8-core DCM @ 3.5 GHz DDR3 MemoryUp to 1 TB SAS SFF Bays Up to 6 HDD or SSD Split Backplane support I/O Expansion Slots in CECPCIe 8x: 6 slots ( Hot Swap ) GX++ Slots 1 socket: 0 2-4 sockets: 2 Integrated I/O Controller SAS ( Dual ) plus SATA Standard RAID 0, 1, & 10 Optional RAID 5 & 6 Integrated Multifunction Card (IMFC) 4 Ethernet (Dual 10 Gb & Dual 1 Gb or Quad 10Gb); 2 USB, 1 serial Media Bays1 Slim-line for DVD 12X PCIe I/O DrawersMax 4 Ultra SSD DrawerMax 2 EXP24S DrawerMax 51 Redundant Power Redundant Cool Yes 3 Anos de Manutenção 24 x 7

42 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 42 Resumo da Unidade Agora você é capaz de:  Descrever as vantagens aos clientes dos servidores IBM Power Systems e seus produtos relacionados.  Identificar e posicionar a atual gama de servidores IBM POWER7 Express

43 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 43 This document was developed for IBM offerings in the United States as of the date of publication. IBM may not make these offerings available in other countries, and the information is subject to change without notice. Consult your local IBM business contact for information on the IBM offerings available in your area. Information in this document concerning non-IBM products was obtained from the suppliers of these products or other public sources. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give you any license to these patents. Send license inquires, in writing, to IBM Director of Licensing, IBM Corporation, New Castle Drive, Armonk, NY 10504-1785 USA. All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. The information contained in this document has not been submitted to any formal IBM test and is provided "AS IS" with no warranties or guarantees either expressed or implied. All examples cited or described in this document are presented as illustrations of the manner in which some IBM products can be used and the results that may be achieved. Actual environmental costs and performance characteristics will vary depending on individual client configurations and conditions. IBM Global Financing offerings are provided through IBM Credit Corporation in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates are based on a client's credit rating, financing terms, offering type, equipment type and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without notice. IBM is not responsible for printing errors in this document that result in pricing or information inaccuracies. All prices shown are IBM's United States suggested list prices and are subject to change without notice; reseller prices may vary. IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply. Any performance data contained in this document was determined in a controlled environment. Actual results may vary significantly and are dependent on many factors including system hardware configuration and software design and configuration. Some measurements quoted in this document may have been made on development-level systems. There is no guarantee these measurements will be the same on generally-available systems. Some measurements quoted in this document may have been estimated through extrapolation. Users of this document should verify the applicable data for their specific environment. Special Notices

44 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 44 IBM, the IBM logo, ibm.com, AIX, AIX (logo), AIX 5L, AIX 6 (logo), AS/400, Active Memory, BladeCenter, Blue Gene, Chiphopper, DB2, DB2 Universal Database, DS4000, DS6000, DS8000, EnergyScale, Enterprise Workload Manager, ESCON, GPFS, HACMP, HACMP/6000, i5/OS, i5/OS (logo), IBM Business Partner (logo), IBM Systems Director Active Energy Manager, IntelliStation, iSeries, LoadLeveler, Lotus, Lotus Notes, Micro- Partitioning, Notes, Operating System/400, OS/400, PartnerLink, PartnerWorld, POWER, Power Architecture, Power Everywhere, Power Family, POWER Hypervisor, Power Systems, Power Systems (logo), Power Systems Software, Power Systems Software (logo), POWER2, POWER3, POWER4, POWER4+, POWER5, POWER5+, POWER6, POWER7, PowerExecutive, PowerHA, PowerPC, PowerVM, PowerVM (logo), pSeries, pureScale, Rational, RISC System/6000, RS/6000, System i, System p, System p5, System Storage, System z, THINK, Tivoli, Tivoli (logo), Tivoli Enterprise Console, WebSphere, Workload Partitions Manager, X-Architecture, xSeries, z/OS and zSeries are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. If these and other IBM trademarked terms are marked on their first occurrence in this information with a trademark symbol (® or ™), these symbols indicate U.S. registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries. AltiVec is a trademark of Freescale Semiconductor, Inc. AMD Opteron is a trademark of Advanced Micro Devices, Inc. InfiniBand, InfiniBand Trade Association and the InfiniBand design marks are trademarks and/or service marks of the InfiniBand Trade Association. Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency which is now part of the Office of Government Commerce. Java and all Java-based trademarks and logos are trademarks or registered trademarks of Oracle and/or its affiliates. Linear Tape-Open, LTO, the LTO Logo, Ultrium, and the Ultrium logo are trademarks of HP, IBM Corp. and Quantum in the U.S. and other countries. Linux is a registered trademark of Linus Torvalds in the United States, other countries or both. Microsoft, Windows and the Windows logo are registered trademarks of Microsoft Corporation in the United States, other countries or both. NetBench is a registered trademark of Ziff Davis Media in the United States, other countries or both. SPECint, SPECfp, SPECjbb, SPECweb, SPECjAppServer, SPEC OMP, SPECviewperf, SPECapc, SPEChpc, SPECjvm, SPECmail, SPECimap and SPECsfs are trademarks of the Standard Performance Evaluation Corp (SPEC). The Power Architecture and Power.org wordmarks and the Power and Power.org logos and related marks are trademarks and service marks licensed by Power.org. TPC-C and TPC-H are trademarks of the Transaction Performance Processing Council (TPPC). UNIX is a registered trademark of The Open Group in the United States, other countries or both. Other company, product and service names may be trademarks or service marks of others. Special Notices (cont.)

45 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 45 Notes on Performance Estimates rPerf for AIX rPerf (Relative Performance) is an estimate of commercial processing performance relative to other IBM UNIX systems. It is derived from an IBM analytical model which uses characteristics from IBM internal workloads, TPC and SPEC benchmarks. The rPerf model is not intended to represent any specific public benchmark results and should not be reasonably used in that way. The model simulates some of the system operations such as CPU, cache and memory. However, the model does not simulate disk or network I/O operations. rPerf estimates are calculated based on systems with the latest levels of AIX and other pertinent software at the time of system announcement. Actual performance will vary based on application and configuration specifics. The IBM eServer pSeries 640 is the baseline reference system and has a value of 1.0. Although rPerf may be used to approximate relative IBM UNIX commercial processing performance, actual system performance may vary and is dependent upon many factors including system hardware configuration and software design and configuration. Note that the rPerf methodology used for the POWER6 systems is identical to that used for the POWER5 systems. Variations in incremental system performance may be observed in commercial workloads due to changes in the underlying system architecture. All performance estimates are provided "AS IS" and no warranties or guarantees are expressed or implied by IBM. Buyers should consult other sources of information, including system benchmarks, and application sizing guides to evaluate the performance of a system they are considering buying. For additional information about rPerf, contact your local IBM office or IBM authorized reseller. ======================================================================== CPW for IBM i Commercial Processing Workload (CPW) is a relative measure of performance of processors running the IBM i operating system. Performance in customer environments may vary. The value is based on maximum configurations. More performance information is available in the Performance Capabilities Reference at: www.ibm.com/systems/i/solutions/perfmgmt/resource.htmlwww.ibm.com/systems/i/solutions/perfmgmt/resource.html

46 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 46 The IBM benchmarks results shown herein were derived using particular, well configured, development-level and generally-available computer systems. Buyers should consult other sources of information to evaluate the performance of systems they are considering buying and should consider conducting application oriented testing. For additional information about the benchmarks, values and systems tested, contact your local IBM office or IBM authorized reseller or access the Web site of the benchmark consortium or benchmark vendor. IBM benchmark results can be found in the IBM Power Systems Performance Report at http://www.ibm.com/systems/p/hardware/system_perf.html.http://www.ibm.com/systems/p/hardware/system_perf.html All performance measurements were made with systems running the AIX operating system unless otherwise indicated to have used Linux. For new and upgraded systems, AIX Version 4.3, AIX 5 or AIX 6 were used. All other systems used previous versions of AIX. The SPEC CPU2006 and SPEC CPU2000 benchmarks were compiled using IBM's high performance C, C++, and FORTRAN compilers for AIX and Linux. For new and upgraded systems, the latest versions of these compilers were used: XL C for AIX v11.1, XL C/C++ for AIX v11.1, XL FORTRAN for AIX v13.1, XL C/C++ for Linux v11.1, and XL FORTRAN for Linux v13.1. For a definition/explanation of each benchmark and the full list of detailed results, visit the Web site of the benchmark consortium or benchmark vendor. TPChttp://www.tpc.orghttp://www.tpc.org SPEChttp://www.spec.orghttp://www.spec.org LINPACKhttp://www.netlib.org/benchmark/performance.pdfhttp://www.netlib.org/benchmark/performance.pdf PTC Creo (formerly Pro/E)http://www.ptc.com/products/creo/http://www.ptc.com/products/creo/ GPC http://www.spec.org/gwpg/http://www.spec.org/gwpg/ VolanoMark http://www.volano.comhttp://www.volano.com STREAMhttp://www.cs.virginia.edu/stream/http://www.cs.virginia.edu/stream/ SAP http://www.sap.com/solutions/benchmark/index.epxhttp://www.sap.com/solutions/benchmark/index.epx Oracle Applicationshttp://www.oracle.com/us/solutions/benchmark/apps-benchmark/index-166919.htmlhttp://www.oracle.com/us/solutions/benchmark/apps-benchmark/index-166919.html ANSYS FLUENThttp://www.ansys.com/Support/Platform+Support/Benchmarks+Overviewhttp://www.ansys.com/Support/Platform+Support/Benchmarks+Overview TOP500 Supercomputershttp://www.top500.org/http://www.top500.org/ Ideas Internationalhttp://www.ideasinternational.com/Free-Advisory/Benchmark-Gatewayhttp://www.ideasinternational.com/Free-Advisory/Benchmark-Gateway Storage Performance Councilhttp://www.storageperformance.org/resultshttp://www.storageperformance.org/results Notes on Benchmarks and Values

47 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 47 Notes on HPC Benchmarks and Values The IBM benchmarks results shown herein were derived using particular, well configured, development-level and generally-available computer systems. Buyers should consult other sources of information to evaluate the performance of systems they are considering buying and should consider conducting application oriented testing. For additional information about the benchmarks, values and systems tested, contact your local IBM office or IBM authorized reseller or access the Web site of the benchmark consortium or benchmark vendor. IBM benchmark results can be found in the IBM Power Systems Performance Report at http://www.ibm.com/systems/p/hardware/system_perf.html.http://www.ibm.com/systems/p/hardware/system_perf.html All performance measurements were made with systems running AIX or AIX 5L operating systems unless otherwise indicated to have used Linux. For new and upgraded systems, the latest versions of AIX were used. All other systems used previous versions of AIX. The LINPACK, and Technical Computing benchmarks were compiled using IBM's high performance C, C++, and FORTRAN compilers for AIX and Linux. For new and upgraded systems, the latest versions of these compilers were used: XL C for AIX V11.1, XL C/C++ for AIX V11.1, XL FORTRAN for AIX V13.1, XL C/C++ for Linux V11.1, and XL FORTRAN for Linux V13.1. Linpack HPC (Highly Parallel Computing) used the current versions of the IBM Engineering and Scientific Subroutine Library (ESSL). For Power7 systems, IBM Engineering and Scientific Subroutine Library (ESSL) for AIX Version 5.1 and IBM Engineering and Scientific Subroutine Library (ESSL) for Linux Version 5.1 were used. For a definition/explanation of each benchmark and the full list of detailed results, visit the Web site of the benchmark consortium or benchmark vendor. SPEChttp://www.spec.orghttp://www.spec.org LINPACKhttp://www.netlib.org/benchmark/performance.pdfhttp://www.netlib.org/benchmark/performance.pdf PTC Creo (formerly Pro/E)http://www.ptc.com/products/creo/http://www.ptc.com/products/creo/ GPC http://www.spec.org/gwpg/http://www.spec.org/gwpg/ STREAMhttp://www.cs.virginia.edu/stream/http://www.cs.virginia.edu/stream/ TOP500 Supercomputershttp://www.top500.org/http://www.top500.org/ AMBERhttp://ambermd.org/http://ambermd.org/ GAMESShttp://www.msg.chem.iastate.edu/gamesshttp://www.msg.chem.iastate.edu/gamess GAUSSIANhttp://www.gaussian.comhttp://www.gaussian.com ANSYS FLUENThttp://www.ansys.com/services/hardware-support-db.htmhttp://www.ansys.com/services/hardware-support-db.htm ABAQUShttp://www.simulia.com/support/v68/v68_performance.phphttp://www.simulia.com/support/v68/v68_performance.php ECLIPSEhttp://www.sis.slb.com/content/software/simulation/index.asp?seg=geoquest&http://www.sis.slb.com/content/software/simulation/index.asp?seg=geoquest& MM5http://www.mmm.ucar.edu/mm5/http://www.mmm.ucar.edu/mm5/ MSC.NASTRANhttp://www.mscsoftware.com/support/prod%5Fsupport/nastran/performance/v04_sngl.cfmhttp://www.mscsoftware.com/support/prod%5Fsupport/nastran/performance/v04_sngl.cfm STAR-CDhttp://www.cd-adapco.com/products/star_cd/performance/406/index.htmlhttp://www.cd-adapco.com/products/star_cd/performance/406/index.html NAMDhttp://www.ks.uiuc.edu/Research/namdhttp://www.ks.uiuc.edu/Research/namd HMMERhttp://hmmer.janelia.org/http://hmmer.janelia.org/ http://powerdev.osuosl.org/project/hmmerAltivecGen2mod


Carregar ppt "© 2013 IBM Corporation Follow us Learn more at This document is for IBM and IBM Business."

Apresentações semelhantes


Anúncios Google