A apresentação está carregando. Por favor, espere

A apresentação está carregando. Por favor, espere

IBM System x and BladeCenter Webcast BladeCenter

Apresentações semelhantes


Apresentação em tema: "IBM System x and BladeCenter Webcast BladeCenter"— Transcrição da apresentação:

1 IBM System x and BladeCenter Webcast BladeCenter
Vitor Santiago Breguedo Systems Management & Product Specialist CTSS = Channel Technical Sales Specialist Enablement BP Technical This document is for IBM and IBM Business Partner use only It is not intended for customer distribution or use with customers. © 2011 IBM Corporation

2 IBM BladeCenter http://www-03.ibm.com/systems/bladecenter/?lnk=mhpr
42 servidores de 1U 42 lâminas HS22

3 Portal BladeCenter - Produtos

4 A economia de energia paga a solução em até 3 anos
Desafios de TI Public Internet/ Intranet Clients Muitas Falhas Alto custo de Downtime Duplicidade de componentes Qualidade vs Custo Firewalls Routers (Layer 3 Switches) Redução de 35% no custo de energia Redução de até 44% nos custos de gerenciamento Redução de 50% do espaço do DataCenter Menos componentes = Menor Downtime A economia de energia paga a solução em até 3 anos Típicas Reduções Layer 4-7 Switches Alto custo de energia, Fans, utilização e eficiência. Layer 2 Switches Network Servers Application Servers Security Servers Application Servers Web Servers Security Gateway File Servers WebSphere Application Servers Alto Custo da Hora Técnica Gerenciamento Local/Remoto Firmware Updates Networking & Storage Alto custo de espaço Limitações físicas Racks cheios e pouca energia Storage Network Storage Network SAN

5 Public Internet/ Intranet Clients Routers (Layer 3 Switches) Firewalls Desafios de TI Layer 4-7 Switches Complexidade, Custos, Riscos, Cabos, Fontes, Fans, Espaço Físico = Custos de Operação, Risco e gerencimaneto descentralizado Layer 2 Switches Storage Network Storage Network SAN

6 Public Internet/ Intranet Clients Routers (Layer 3 Switches) Firewalls Desafios de TI Layer 4-7 Switches Riscos de Segurança e custos. Complexidade continuada, cabos, custos operacionais e espaço físico Storage Network Storage Network SAN

7 A economia de energia paga a solução em até 3 anos
Desafios de TI Baixo risco de acesso físico indevido ao sistema. Maior Segurança Elimina 80% dos cabos de rede Economia de energia eliminando dispositivos externos Tecnologias que evitam interrupções Vantagens A economia de energia paga a solução em até 3 anos Public Internet/ Intranet Clients Routers (Layer 3 Switches) Firewalls Custos, Complexidade, Riscos, Cabos de Fibra Ótica, Transceivers = Custos Operacionais, Riscos e Gerenciamento descentralizado. Storage Network Storage Networks SAN

8 Resumindo, sua infraestrutura enxuta!
Layer 2 Switches Storage Fibre Switches File Servers Web Security Gateway WebSphere Application Network SAN Layer 4-7 Switches Public Internet/ Intranet Clients Routers (L3 Switches) Firewalls Gerenciamento simplificado Redução do cabeamento SAN Redução do cabeamento LAN Consolidação dos switches no chassi Eliminação dos custos com KVM Redução dramática nos custos com PDU Preservação do espaço, manutenção da temperatura e consumo elétrico Public Internet/ Intranet Clients Routers Firewalls SAN

9 Ou você quer continuar vivendo perigosamente ? ? ?

10 Entendendo a tecnologia BladeCenter!
Integração e redução da complexidade da infraestrutura de TI Estrutura de armazenamento e suporte a servidores de alta densidade (Lâminas) Voltados à economia de espaço, energia, cabeamento e arrefecimento dos DataCenters e CPDs Padrão rack-mountable de 7 a 12Us Capacidade de acomodar servidores e módulos de I/O, todos Hot-Swap Componentes redundantes Light Path Diagnostics

11 Simplificação com BladeCenter, para ter benefícios!
14 Node 1U 14U 28 power cables 84 fans 28 power supplies 36 Ethernet cables 14 KVM cables 4 Power Distribution Units 2x KVM Switches Power consumption: 7.7KVA Heat dissipation: BTU/hr 7U 4 power supplies 4 power cables 2 fans 8 Ethernet cables 4 FC cables 1 Power Distribution Units No KVM Switches Power consumption: 4KVA Heat dissipation: BTU/hr Power Systems Technical Support for AIX and Linux

12 Componentes da solução BladeCenter – Parte 1
IBM Blade - with its cover on - ready for insertion into the BladeCenter “Server on a card” – cada Blade possui seu próprio: Processador Memória Ethernet Storage (opcional) Chip de gerenciamento de sistemas O chassis proporciona compartilhamento de: Console de gerenciamento (KVM) Fonte de energia Ventilação Switches de rede Switches de fibra Drive de CD-ROM Drive de diskette Portas USB IBM BladeCenter chassis - 7U rackable Infraestrutura totalmente redundante para máxima disponibilidade e tolerância a falhas

13 Componentes da solução BladeCenter – Parte 2
Servidores Blade Media Tray (DVD, portas USB) Fontes de alimentação redundantes e Hot-Swap Componentes Ethernet Componentes Fibre Channel Componentes Pass-Thru Componentes para conexões de alta velocidade Módulos para armazenamento de discos (BCS) Módulos de Gerenciamento Avançado (AMM)

14 Midplane eficiente, máxima disponibilidade! BladeCenter H Midplane
Midplane Superior Espaço ocupado por uma lâmina Espaço para Ventilação I/O connector Power connector High-speed I/O connector High-speed I/O connector I/O connector Power connector Midplane Inferior Blade Server BladeCenter H Midplane

15 Lâminas possuem conexões redundantes!
GB Ethernet / Fibre Channel KVM Drive de DVD Sinal de Video Gerenciamento Alimentação Elétrica Quais lâminas possuem essa característica?? Todos os sinais acima são duplicados nesse conector Todos os modelos!!

16 Família IBM – BladeCenter – 1) Chassis

17 BladeCenter E - Visão Frontal
USB port Optical drive (optional) Alças Painel Light Path Diagnostics 7U 28” Peso: Até 113kg (populada) 14 baias de 30mm Slot do Cartão de Serviço

18 BladeCenter E – Visão Traseira
Power module bay 1 with PFA Hot-swap Advanced Management Module (AMM) Power module bay 3 with PFA Switch Module Bay 1 (dedicated Ethernet) Switch Module Bay 3 Switch Module Bay 4 Switch Module Bay 2 (dedicated Ethernet) Power module bay 4 with PFA Hot-swap redundant blowers with PFA Light Path Diagnostics panel Power module bay 2 with PFA Optional hot-swap redundant Advanced Management Module (AMM)

19 BladeCenter H – Visão Frontal
Two bays behind bezel for 2980W 95% efficient hot-swap redundant power supplies with PFA and three replaceable fans on each 29” Front of Light Path Diagnostics Panel 9U Hot-swap media tray Panel inc two USB ports, and Light Path Diagnostics panel (CD ROM optional) 14 bays for support up to 14 blades Handles Slot for service reference card Two bays behind bezel for 2980W hot-swap redundant power supplies with PFA and three replaceable fans on each Weight: Up to 158Kg (populated)

20 BladeCenter E – Visão Traseira
High-speed switch module bays Redundant power input Redundant power input Switch module bay 1 (dedicated ethernet) Hot-swap Advanced Management Module (AMM) Dedicated bridge module slot Switch module bay 3 (or bridge slot) Switch module bay 2 (dedicated ethernet) Optional hot-swap redundant Advanced Management Module (AMM) Dedicated bridge module slot Switch module bay 4 (or bridge slot) Light Path Diagnostics panel Aggregated serial connector Hot-swap redundant blowers with PFA (directly AC powered – High Efficency 94%) High-speed switch module bays

21 Chassi H traseira – Usando MSIM
OU

22 BladeCenter S – Visão Frontal
Hot-swap media tray with optional optical, two USB ports, Light Path Diagnostics panel, and two battery backup bays Front of Light Path Diagnostics Panel 7U 29” Slot for service reference card Two storage module bays 6 blade server bays Weight: 90 pounds Up to 240 pounds (populated)

23 BladeCenter S – Visão Traseira
Module Bay 1 for Ethernet Module (via integrated ethernet on blade) Module Bay 3 for Ethernet, FC, or SAS for DSM (via CFFv or CIOv adapter on blade) Hot-swap Advanced Management Module (AMM) Two standard hot-swap redundant watt power supplies (1450W at 220V) with PFA. (Image shows US C19 Plugs, UK have C14.) 7U LED panel Module Bay for optional Serial Pass-Through Module Two optional hot-swap redundant watt power supplies (1450W at 220V) with PFA Four hot-swap redundant cooling fans with PFA Module Bay 2 for ethernet use (via CFFh adapter on blade) Module Bay 4 for Ethernet, FC, or SAS for DSM (via CFFv or CIOv adapter on blade)

24 IBM BladeCenter - Lâminas
HS23E Dois Sockets Xeon E5-2400 Series 16 DIMM slots 8 I/O portas Max 192GB HS23 Dois Socket Xeon E5-2600 Series 16 DIMM slots 8 I/O portas Max 256GB HS22 Dois sockets Xeon 5600 Series 12 DIMM slots 8 I/O portas Max 192GB HS22V Dois Socket Xeon 5600 Series 18 DIMM slots 8 I/O portas Max 288GB HX5 Dois Socket Xeon 7500 Series Xeon 6500 Series Xeon E7 16 DIMM slots 8 I/O portas Max 256GB HX5 + MAX5 Dois Socket Xeon 7500 Series Xeon 6500 Series Xeon E7 40 DIMM slots 8 I/O portas Max 640GB HX5 Quatro Socket Xeon 7500 Series Xeon E7 32 DIMM slots 16 I/O portas Max 512GB

25 IBM BladeCenter HS22 Redundant midplane connections
PCI-e connector (CIOv) Internal USB connector (Embedded Hypervisor) Up to two Intel Xeon Processors with PFA Up to two hot-swap SAS, SATA, or Solid State drives with PFA LSI 1064 RAID controller PCI-e connector (CFFh) Dual gigabit Ethernet Broadcom 5709S controller Light Path Diagnostics Panel Twelve ECC VLP DDR3 DIMM sockets with PFA 192GB with 16GB DIMM Unified Extensible Firmware Interface (UEFI) Intelligent Platform Module Interface (IPMI) 2.0 Trusted Platform Module (TPM) 1.2 Integrated Mangement Module (IMM) with cKVM

26 IBM BladeCenter HS22V PCI-e connector (CIOv)
Redundant midplane connections Internal USB connector (Embedded Hypervisor) Flip Down Operator Panel PCI-e connector (CFFh) Integrated Mangement Module (IMM) with cKVM Dual gigabit Ethernet Broadcom controller Up to two Intel Xeon Processors with PFA Eighteen DDR3 VLP DIMM sockets with PFA 288GB with 16GB DIMM Up to two 1.8” solid state drives Unified Extensible Firmware Interface (UEFI) Intelligent Platform Module Interface (IPMI) 2.0 Trusted Platform Module (TPM) 1.2 Light Path Diagnostics Panel

27 IBM BladeCenter HS23 Integrated 1Gb/10GbE LOM USB socket
2x Intel Xeon Processors 2x IO Expansion Slots 1x CIOv +1x CFFh) 2x hot-swap drive bays (SAS, SATA or Solid State) 16x VLP DDR3 Memory (256GB Max / 1600MHz Max) 10Gb Interposer Card Light Path Diagnostics Panel (Located on other side of blade)

28 IBM BladeCenter HS23E 2x Intel Xeon Processors (Romley EN)
Integrated 1GbE Broadcom Dual and redundant power & I/O connectors 2x IO Expansion Slots 1x CIOv +1x CFFh) 12x VLP DDR3 Memory (192GB Max / 1600MHz Max) 2x hot-swap drive bays (SAS, SATA or Solid State)

29 IBM BladeCenter HX5 Unified Extensible Firmware Interface (UEFI)
Intelligent Platform Module Interface (IPMI) 2.0 Trusted Platform Module (TPM) 1.2 QPI speed burst or scalability card slot SSD expansion connector for up to two 1.8” drives PCI-e connector (CIOv) QPI speed burst or scalability card slot Second two socket HX5 blade Two socket HX5 blade Four socket HX5 blade with FlexNode partitioning Sixteen ECC VLP DDR3 DIMM sockets with PFA 16GB DIMM support (256GB) at 1066MHz USB hypervisor connector Two Xeon processor sockets with PFA PCI-e connector (CFFh) Redundant midplane connections

30 HX5 – 2- & 4-Socket Blade Visão superior do sistema com 4 processadores
2x IO Expansion Slots (1x CIOv + 1x CFFh) 2x SSD drives (1.8”) 16x VLP DDR3 Memory 2x Intel Xeon EX CPUs 8x memory buffers 2x 30mm nodes Scale Connector Additional Features Internal USB for embedded hypervisor Dual & redundant I/O and Power Optional RAID 5 with battery backed cache IMM & UEFI

31 MAX5 para HX5 HX5+MAX5 Configuration MAX5 HX5 6x memory buffers
eX5 Chipset HX5+MAX5 Configuration 2S, 40D, 8 I/O ports, 60m 24x VLP DDR3 memory

32 BladeCenter HX5 – Conector para escalar 4S ou MAX5!

33 Portfólio IBM BladeCenter de Adaptadores e Switches
Switches Eth, FC e SAS Switches de alta velocidade Adaptadores Eth, FC e SAS Adaptadores de Alta velocidade Ethernet – Fibre Channel – InfiniBand – FCoE – SAS – iSCSI – Virtual Fabric

34 Inter Switch Links Ports 13-14
BladeCenter – Arquitetura de comunicação para I/O 1 2 3 4 Inter Switch Links Ports 13-14 Expansion cards add NIC ports 3 and 4 to blade servers, connect to switches 3 & 4 respectively

35 Exemplo usando BladeCenter H para caminhos de I/O

36 IBM BladeCenter H I/O IBM BladeCenter H IBM BladeCenter HS22
2 x Gb Ethernet 2 x 4Gb Fibre 2 x 8Gb Fibre 2 x SAS Integrated 2 x Gb Ethernet Ethernet Compact I/O “Vertical” (CIOv) Adapter CFFh Ethernet CIOv Redundant Midplane IBM BladeCenter H IBM BladeCenter HS22 Redundant Midplane Ethernet CIOv CFFh Compact Form Factor “Horizontal” (CFFh) Adapter 2 x Gb Ethernet and 2 x 8Gb Fibre 2 x 10Gb Ethernet 4 x 10Gb Ethernet 2 x 10Gb Converged 2 x Virtual Fabric 2 x InfiniBand

37 Ferramentas de desenvolvimento de SKILL e suporte em tecnologia BladeCenter!

38 Obrigado !


Carregar ppt "IBM System x and BladeCenter Webcast BladeCenter"

Apresentações semelhantes


Anúncios Google