1 © 2013 IBM Corporation Follow us @IBMpowersystems@IBMpowersystems Learn more at www.ibm.com/powerwww.ibm.com/power This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients IBM Power Systems AM71/AS600 Technical Sales Common Skills Unidade 8 – I/O Expansion

2 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 2 Objetivos Os seguintes tópicos serão cobertos nesta unidade:  Tópico 1 – I/O Demonstrações de planejamento  Tópico 2 – Gavetas de Expansão de I/O e Loops

3 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 3 Quanto eu preciso saber sobre recursos de I/O?  Depende de sua função  Depende de seus clientes “Os produtos estão em constante mudanças, como me mantenho atualizado?”  Facts and features Facts and features  Cartas de Anúncio  Redbooks  Este curso

4 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 4 Tópico 1 – I/O Demonstrações de planejamento Objetivos do tópico – depois de estudar este tópico você deverá estar apto a:  Identificar recursos de I/O que estão próximos a descontinuar  Guiar clientes que consideram atualizar e planejam migrar recursos de I/O

5 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 5 Power Systems – Planejamento e demonstração de Hardware  IBM planeja que os servidores POWER7 sejam a última geração de servidores Power que irão suportar adaptadores PCI-X e PCI-X I/O drawers.  Adaptadores e I/O drawers PCIe oferecem maior performance em servidores POWER6 e POWER7 e provê a melhor base para servidores futuros POWER4POWER7POWER6POWER5 Sem PCI-X IBM's statements regarding its plans, directions, and intent are subject to change or withdrawal without notice at IBM's sole discretion. Information regarding potential future products is intended to outline our general product direction and it should not be relied on in making a purchasing decision. The information mentioned regarding potential future products is not a commitment, promise, or legal obligation to deliver any material, code or functionality. Information about potential future products may not be incorporated into any contract. The development, release, and timing of any future features or functionality described for our products remains at our sole discretion.

6 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 6  Historicamente, IBM descontinuou outros I/O antigos –Novas gerações de servidores foram introduziodos –I/Os antigos não atende os requisitos funcionais ou performance de novos servidores  Para Power servers planejado para seguir a linha POWER7: –IBM planeja suportar discos SAS nos futuros servidores Power –IBM não planeja suportar discos SCSI após POWER7, incluindo: #5786 EXP24 SCSI Disk Drawer que provê baias 3.5-inch SCSI #5782 PCI-X 1.5GB Cache SCSI Adapter com suporte a #5786 EXP24 –IBM planeja dar suporte non-disk SCSI devices Quando conter slots PCI-X disponíveis Adaptador #5736 PCI-X SCSI terá suporte quando quando conectado a tape ou optical drives IBM's statements regarding its plans, directions, and intent are subject to change or withdrawal without notice at IBM's sole discretion. Information regarding potential future products is intended to outline our general product direction and it should not be relied on in making a purchasing decision. The information mentioned regarding potential future products is not a commitment, promise, or legal obligation to deliver any material, code or functionality. Information about potential future products may not be incorporated into any contract. The development, release, and timing of any future features or functionality described for our products remains at our sole discretion. POWER5 POWER6+ POWER6 POWER5+ POWER7 POWER7+ Sem disco SCSI, use SAS Power Systems – Planejamento e demonstração de Hardware

7 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 7 Topic 2 – Gavetas de Expansão de I/O e Loops Objetivos do tópico – depois de estudar este tópico você deverá estar apto a:  Identificar as I/O drawers suportadas para sistemas POWER7  Discutir o suporte Power Systems para 12X loops e adaptadore GX entre a linha de produtos  Guiar clientes que consideram adquirir, atualizar e planejam migrar recursos de I/O

8 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 8 I/O Expansion Drawers

9 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 9 I/O Drawers – as variantes  Rack 19” ou 24”?  PCIe ou PCI-X cards?  2.5” SFF (small form factor) ou 3.5” drives?  SFF Gen-1 ou Gen-2?  SAS ou SCSI drives?  HDDs ou SSDs?  12X loop disponível?

10 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 10 I/O Drawers – As Soluções  PCIe cards e SFF Gen-1 SAS drives –Para 19” rack: FC #5802 –Para 24” rack: FC #5803  PCIe cards somente (sem drives) –Para 19” rack: FC #5877 –Para 24” rack: FC #5873  PCI-X cards e 3.5” SCSI drives –Para 24” rack: FC #5797/5798 –Não disponível para rack 19”  PCI-X cards somente (sem drives) –Para 19” rack: FC #5796 –Para 19” rack: 7314-G30 –Não disponível para rack 24”  SSD drives somente –Para 19” rack FC #5888 (POWER7) FC #EDR1 (POWER7+) –Não disponível para rack 24”  2.5” SFF Gen-2 SAS drives somente –Para 19” rack: FC #5887 –Não disponível para rack 24”  3.5” SAS drives somente –Para 19” rack: FC #5886 –Não disponível para rack 24”  3.5” SCSI drives somente –Para 19” rack: FC #5786 –Para 19” rack: 7031-D24 –Não disponível para rack 24” Suportado mas não pode ser encomendado

11 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 11 PCIe 19” 12x I/O Drawer  Dimensões: 4U x 19” ‏  Feature Code #5802 –SAS Drives: 18 ( SFF Gen-1 Drives)‏ Requer adaptador –PCIe Slots: 10 2.5 GB/sec ( x8 )‏ –Partition Modes: Single Partition: 18 drives Dual Partition: 9 drives por partition Quad Partition: 5 / 4 / 4 / 5 drives por partition  Feature Code #5877 –PCIe Slots: 10 2.5 GB/sec ( x8 )‏ Diskless (não possui baias de discos)  Server Loop Attachment: 12X DDR –Máximo de dois drawers/loop –Dual ports por controller –12 GB/sec por porta (Pico)‏ –9.5 GB/sec por porta (Contínuo) 5802 5877

12 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 12 PCIe 24” 12x I/O Drawer  Dimensões: 4U x 24”  Feature Code #5803 –PCIe Slots: 20 2.5 GB/sec ( x8 ) ‏ –SAS Drives: 26 ( SFF Gen-1 Drives )‏ –Requer adaptador(es) –Drawer Partition Modes: Single Partition: 26 drives Dual Partition: 13 drives por partition Quad Partition: 7 / 6 / 6 / 7 drives por partition  Feature Code #5873 –PCIe Slots: 20 2.5 GB/sec ( x8 )‏ –Diskless ( não possui baias de discos )  Server Loop Attachment: 12X DDR –Máximo de um drawer/loop –Dual ports por controller –9.1 GB/sec por porta (Contínuo)‏ front rear

13 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 13 Back Front 16 DASD GX Dual Port 12X Channel Connections PCI-X 24” 12x I/O Drawer  Suportado no Power 795  Dimensões: 4U x 24”  Feature code: #5797 – PCI-X slots 20 6 PCI-X 14 PCI-X 2.0 (266MHz) Todos adaptadores 64bits –16 Hot-Plug bays: disco 3.5” Ultra3 SCSI  Feature code: #5798 (idem #5797 mas somentes o CEC frame)  Server Loop Attachment: 12X SDR –Máximo de um drawer/loop –GX Dual Port 12X Channel –12x SDR Interface –30 Gb/sec  Blind Swap Adapter Cards  Hot Drawer Add  Hot Pluggable SCSI Cntrl PCI-X 133 PCI-X 266 Dual or Single Path SCSI Cntrl SCSI Cntrl SCSI Cntrl

14 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 14 PCI-X 19” 12X I/O Drawer  Feature code #5796: –PCI-X 2.0 (266 MHz) slots: 6 –Smart IOAs somente – sem IOPs –Adaptadores Hot pluggable –Power e Cooling redundante e hot-swappable  Server Loop Attachment: 12X SDR –Máximo quatro drawers por loop  Suportado em 720, 740, 770 e 780 #5796  4U  ½ wide drawer  Imagem mostra duas #5796s no enclosure #7314

15 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 15 19-inch I/O Drawer conexões e configurações  Usando um adaptador 12X GX para o I/O drawer –DDR para #5802/5877, SDR para #5796/5714-G30  Se o servidor for limitado no numero de loops, a seleção do I/O drawer pode ser impactado  Pode usar cabos 12X para 4X para conectar em IB switch para clustering 12X PCI-X DDR Max 4 por loop 6 slots por drawer 12X PCIe Max 2 por loop 10 slots por drawer Não usar PCI-X e PCIe no mesmo loop 12X ModelMax loops 7100 720 4-core 0 720 6/8-core 1 7300 or 1* 7402** 7708 7808 #5802 or 5877 #5796 5714-G30 #5796 5714-G30 * 1 se 730 modelo “C/D”, zero se modelo “B” ** para 2o loop requer os dois sockets de processador populados

16 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 16  Usando adaptadores 12X GX para o I/O drawers 12X PCI-X DDR Max 4 por loop 6 slots por drawer 12X PCIe Max 2 por loop 10 slots por drawer PCI-X 12X Drawers NÃO é suportado em POWER7+ 750/760 ModelMax loops 750 1 DCM 0 750 2-4 DCM 2 760 1 DCM 0 760 2-4 DCM 2 #5802 or 5877 #5796 5714-G30 #5796 5714-G30 Nota: sem slots PCI-X não há I/O SCSI – exemplo: –Sem EXP24 3.5-inch SCSI drawers (#5786 ou 7031-D24) –Sem SCSI tape ou dispositivo ótico (use SAS como alternativa) 19-inch I/O Drawer conexões e configurações

17 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 17 EXP24S SFF Gen2-Bay Expansion Drawer  Dimensões: 2U x 19” drawer  Feature Code: #5887 –24 baias SAS para HDD ou SSD (não contém slots PCIe) –Baias Gen2 (SFF-2)…. Diferente trilho/bandeja vs SFF-1  Suporte SAS SFF HDDs ou SSDs em POWER6 e POWER7  Interconecte: Adaptador(es) SAS PCI ou integrated SAS controller  OS Support: –AIX 5.3 ou superior –IBM i 6.1 ou superior (com ou sem VIOS) (i 6.1.1 ou i 7.1 Load Source é suportado) –Linux REHL 5.6 or superior, SUSE 11 or superior –VIOS 2.2.0.12 ou superior

18 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 18 #5887 EXP24S SAS Adapters/Controllers Suportado em POWER7 ou POWER6*  Adaptadores PCI –PCIe 380 MB Cache SAS RAID Adapter (#5805, #5903) –PCIe Dual-x4 SAS Adapter 3Gb (#5901, #5278) (not with IBM i) –PCIe2 1.8 GB Cache RAID SAS Adapter Tri-port 6 Gb (#5913) –PCI-X 1.5 GB Cache SAS RAID Adapter (#5904, #5906, #5908)  Integrated SAS controllers via integrated SAS port na traseira do CEC –Power 710**/730, Power 720**/740, Power 750/755, Power 760, Power 770/780 –Power 520* **, Power 550*, * POWER6 estrutura de produtos unificados (8203-E4A, 8204-E8A, 8233-EMA, 9117-MMA, 9119-FHA), não em 9408-M25, 9409-M50, 9406-MMA ** Não em 4-core Power 710/720, não em 1-core Power 520 PCI adapter System unit c/ porta SAS

19 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 19 EXP24S Modos 666612 24 IMPORTANTE: Modo #5887 já configurado de fábrica Sem opção de alteração posterior Solicite corretamente!!!! 2 conjuntos de 12 baias AIX, Linux, VIOS (não IBM i) Todos adaptadores/controladores 4 conjuntos de 6 baias AIX, Linux, VIOS (não IBM i) Somente #5901/5278 Modo 1Modo 2 Modo 4 Nota: em uma solicitação de MES de vários EXP24S, evite mixar diferentes modos. Não há nenhum indicador externamente visível ou chaveador que indique o modo do I/O drawer. 1 conjunto de 24 baias AIX, IBM i, Linux, VIOS Todos adaptadores/controladores

20 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 20 I/O drawer EXP12S Somente Disco para Drives 3.5” SAS  Dimensões: 2U x 19”  Feature code: #5886 –12 baias hot-swap 3.5” SAS drive… –ou 8 baias hot-swap 3.5” SSD bays –HDDs e SSDs não pdem ser misturados  Interconexão: adaptador SAS (PCIe ou PCI-X) ou controladora SAS integrada EXP12S (#5886)

21 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 21 EXP30 Ultra SSD I/O Drawer  Dimensões: 1 U x 19” drawer  Feature Code: #EDR1 –Até 30 SSD –Até 30 x 387 GB drives = até 11.6 TB –Maior performance até 480,000 IOPS (100% read) Até 410,000 IOPS (60/40% read/write) Até 325,000 IOPS (100% write) Até 4.5 GB/s bandwidth –Até 48 drives & 43 TB downstream HDD  Intercoenxão: adaptador GX++ PCIe2 Mais poderoso e eficiente utilização de espaço usando SSDs com IBM Power Systems SODs para ainda mais recursos Não utilize slots PCIe – conecte no slot GX++ 3.1GB write cache SAS adapters integrado no drawer  Ultra performance  Ultra densidade

22 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 22 EXP30 Ultra SSD I/O Drawer  Suportado em: –“Power 770/780 modelo “D” –“Power 710/720/730/740/750/760 modelo “D” –Power 770/780 modelo “C”  OS suportado: –AIX 6.1 ou superior –Linux –IBM i 7.1 TR6 Nativo (não suportado via VIOS) –VIOS  Mínimo de 6 SSD por Ultra Drawer  Todos drives formatados em RAID (não JBOD)  Ativo/Ativo recomendado para alta performance –A/A requer ao menos dois arrays – ideal mesmo número de arrays, uniformemente balanceado  Conectado em um ou dois slots GX++  Duas controladores SAS RAID SAS integradas –3.1GB write cache – protegidos através de redundância #EDR1

23 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 23 EXP30 Ultra SSD I/O Drawer OS Support Levels para #EDR1  AIX –Versão 7.1 com 7100-02 Technology Level, ou superior –Versão 7.1 com 7100-01 Technology Level e Service Pack 6, ou superior –Versão 7.1 com 7100-00 Technology Level e Service Pack 8, ou superior –Versão 6.1 com 6100-08 Technology Level, ou superior –Versão 6.1 com 6100-07 Technology Level e Service Pack 6, ou superior –Versão 6.1 com 6100-06 Technology Level e Service Pack 10, ou superior  Linux –Red Hat Enterprise Linux 6.3 for POWER, ou superior –Red Hat Enterprise Linux 5.7 for POWER, ou superior –SUSE Linux Enterprise Server 11 Service Pack 2, ou superior, com suporte/manutenção SUSE para suportar todas as funcionalidades planejadas  VIOS V2.2.2.0  VIOS V2.2.1.5  IBM i 7.1 TR6 para suporte nativo (não suporta VIOS) –Anúncio Fev 2013 –Suporte #EDR1 somente, não suporta #5888 #EDR1

24 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 24 Ultra Drawer Attachment: GX++ PCIe2 Adapter Power 730  Controladora SAS RAID integrada conecta no servidor Power através de um adaptador GX++ PCIe2 via cabo PCIe  Adaptador GX++ PCIe2 pluga no slot GX++ –NOTA: um loop 12X I/O NÃO pode ser conectado no slot GX++  POWER7+ 710 max de um #EJ0H. Portanto uma 710 pode suportar ½ de um Ultra SSD I/O Drawer (AIX/Linux) Atrás EXP30 Ultra Drawer (#EDR1) 730 Modelo “D” Cabos PCIe #EN05 (1.5m), #EN07 (3m) Cada controladora SAS integrada precisa de um cabo PCIe conectado a um adaptador GX++ PCIe Não use slots PCIe! GX++ PCIe2 Adapter #EJ0H 1 porta GX++ PCIe2 Adapter #EJ0H 1 porta

25 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 25 Ultra Drawer Attachment: GX++ PCIe2 Adapter Power 720/740  Controladora SAS RAID integrada conecta no servidor Power através de um adaptador GX++ PCIe2 via cabo PCIe  Adaptador GX++ PCIe2 pluga no slot GX++ –NOTA: um loop 12X I/O NÃO pode ser conectado no slot GX++ Atrás EXP30 Ultra Drawer (#EDR1) 720/740 Modelo “D” Cabos PCIe #EN05 (1.5m), #EN07 (3m) Não use slots PCIe! GX++ PCIe2 Adapter #EJ03 2 portas Cada controladora SAS integrada precisa de um cabo PCIe conectado a um adaptador GX++ PCIe

26 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 26 Ultra Drawer Attachment: GX++ PCIe2 Adapter Power 750/760 Atrás EXP30 Ultra Drawer (#EDR1) 750/760 Modelo “D” Cabos PCIe #EN05 (1.5m), #EN07 (3m), #EN08 (8m) Não use slots PCIe! GX++ PCIe2 Adapter #1914 2 portas  Controladora SAS RAID integrada conecta no servidor Power através de um adaptador GX++ PCIe2 via cabo PCIe  Adaptador GX++ PCIe2 pluga no slot GX++ –NOTA: um loop 12X I/O NÃO pode ser conectado no slot GX++ Cada controladora SAS integrada precisa de um cabo PCIe conectado a um adaptador GX++ PCIe

27 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 27 Ultra Drawer Attachment: GX++ PCIe2 Adapter Power 770/780 Atrás EXP30 Ultra Drawer (#EDR1) 770/780 Modelo “C” e “D” Cabos PCIe #EN05 (1.5m), #EN07 (3m), #EN08 (8m) Não use slots PCIe! GX++ PCIe2 Adapter #1914 2 portas Cada controladora SAS integrada precisa de um cabo PCIe conectado a um adaptador GX++ PCIe  Controladora SAS RAID integrada conecta no servidor Power através de um adaptador GX++ PCIe2 via cabo PCIe  Adaptador GX++ PCIe2 pluga no slot GX++ –NOTA: um loop 12X I/O NÃO pode ser conectado no slot GX++

28 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 28 Ultra Drawer Attachment Downstream HDD 1U – 30 SSD  Até 78 SAS baias em 5U  Até 54.8TB em apenas 5U – Até 11.6 TB SSD (30 x 387GB drives) – Até 43.2 TB HDD (48 x 900GB drives)  Zero PCIe slots ! Conexão direta GX++  Com imenso IOPs 2U – 24 HDD Até dois * EXP24S #5887 disk drawers roda por duas integrated SAS controllers no #EDR1 Ultra Drawer #EDR1 Ultra Drawer IBM i suporta um downstream EXP24S do #EDR1. Portanto Até 54 Baias SAS em 3U Até 32TB em apenas 3U

29 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 29 Ultra Drawer Attachment Downstream HDD Servers Modelo “D” SAS EX Cables: #5926 (1.5m) #3675 (3m) #3680 (6m) Não use slots PCIe! 2 ports Modo 1 somente HDD somente Modo 1 somente HDD somente #5887 EXP24S * IBM i supports up to one downstream #5887 EXP24S  Integrated SAS RAID controllers no Ultra Drawer roda as 30 baias SSD na Ultra Drawer MAIS até 48 baias HDD SAS em até dois #5887 EXP24S Drawers *  Cada duas integrated SAS controllers precisa de um cabo SAS EX conectado na #EXP24S Drawer.  Nota: somente HDD, não é suportado SSD no downstream #5887 EXP24S e o EXP24S deve estar no modo 1 Atrás do EXP30 Ultra Drawer (#EDR1)

30 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 30 Tecnologia Ultra Drawer SAS Controller  Mais poderoso adaptador SAS já apresentado pela IBM!  Elevados níveis de performance oferecido sem usar nenhum slot PCIe  Duas alta-performance, integrated SAS controllers –3.1GB write cache em cada –Trabalha em par, oferece espelhamento dos dados no write cache e redundância da controller –Conteúdo do cache protegido por memória flash embutida em caso de falha de energia –Controladora entrega RAID 0, RAID 5, RAID 6, e RAID 10 para AIX, Linux e VIOS –Controladora provê RAID 5 e RAID 6 para IBM i  2GB on-card instruction memory (adicional para 3.1GB write cache)  Conexão GX++ dedicada para baixa latência e sem contenção de PCIe EXP30 Ultra SSD SAS controller

31 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 31 1.Descontinuado do mercado, não pode ser pedido pela fábrica IBM. Pode migrar I/O existente para conectar. 2.Embora possa mixar 12X PCI-X DDR I/O drawers com 12X PCIe I/O drawers no sistema com dois ou mais loops, em um loop deve ser todos PCIe ou todos PCI-X DDR I/O drawers. 3.I/O drawers somente de discos não são suportados no P710 4-core. 4.12X I/O drawers ou disk-only drawers não são suportados no P720 4-core 5.710/720/730/740 modelo “D” somente. Um único Power 710 não pode conectar em um #EDR1 por si só, mas pode conectar em conjunto com outro servidor. Power 720, 730, 740 pode conectar mais Ultra Drawers que mostrado, assumindo conexão em conjunto com outros servidores. 6.Original EXP30 Ultra SSD drawer #5888 não mostrado como somente suportado em 710-740 modelo “C”. Ainda pode ser configurado. POWER7 Server I/O Drawer Attachment I/O DrawerPower 710 Express 0 loops Power 730 Express 0 – 1 loops Power 720 Express 0 – 1 loops Power 740 Express 0-2 loops #57970000 #57980000 #58030000 #58730000 7314-G3000Max 4 4 Max 8 #579600Max 4 4 Max 8 #58020Max 2Max 2 4 Max 4 #58770Max 2Max 2 4 Max 4 #EDR1Max ½ 3,5 Max 1 5 Max 1 4,5 Max 2 5 #5886Max 8 3 Max 28Max 28 4 28 #5887Max 4 3 Max 14Max 14 4 Max 14 24” rack mount 19” rack mount

32 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 32 1.Descontinuado do mercado, não pode ser pedido pela fábrica IBM. Pode migrar I/O existente para conectar. 2.Ultra SSD drawer suportado somente no POWER7+ (Modelos D) e POWER7 770 e 780 Modelos C POWER7 Server I/O Drawer Attachment (cont’d) I/O DrawerPower 750 Power 760 0 -2 loops Power 770 0 – 8 loops Power 780 0- 8 loops Power 795 1 -32 loops #579700030 #579800030 #580300032 #587300031 7314-G300Max 32 0 #57960Max 32 0 #5802Max 4Max 16 0 #5877Max 4Max 16 0 #EDR1 2 Max 2Max 8 0 #5886Max 27Max 110 Max 185 #5887Max 51Max 126 Max 168 24” rack mount 19” rack mount

33 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 33 12X Cables Length Cabos SDR – use para PCI-X 12X I/O drawers. Não use para PCIe I/O drawers. Cabos DDR – use para PCIe ou para PCI-X 12X I/O drawers 0.6 meter#1829#1861 1.5 meter#1830#1862 2.5 meter#1831#1863 3.0 meter#1840#1865 8.0 meter#1834#1864 Cabos 12X DDR possuem mesmo conector verde escuro como os cabos 12X SDR, mas possuem etiquetas diferentes. Cuidado. Fisicamente os cabos antigos podem conectar no PCIe drawers – tamanho/codificação identicos “D” para DDR Cabos SDR descontinuados do mercado, mas suportado em PCI-X I/O drawers Pode mixar cabos DDR e SDR no mesmo loop IF conectando PCI-X I/O drawers. Etiqueta cabo DDR

34 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 34 Slots GX Power 710/730  GX++ Slot 1: –Disponível em 710/730 –Para adaptadores GX++  GX++ Slot 2: –Disponível na 730 –NÃO disponível no 710 –Compartilha espaço com slotPCIe “C7” LAN –Para adaptadores GX++ Figura mostra modelo “C”, mas é o mesmo para slots modelos “B” e “D”

35 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 35 O que eu conecto nos slots GX? Adaptadores GX++ 710/730 Usado para 4X Channel Attach Conexão para Switch 4X DDR InfiniBand (AIX/Linux) 12X Channel Attach * Conexão para 12X I/O drawers * #5802/#5877 (AIX/IBM i/Linux) PCIe2 x8 * Conexão EXP30 Ultra I/O SSD Drawer (#5888 para modelo “C” & #EDR1 para modelo “D”) * (AIX/IBM i**/Linux) * Disponível somente em modelos “C/D” ** IBM i disponível somente em modelos “D”

36 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 36 710/730 GX++ Adapters – Some Model Details “C/D” models: 8231-E1C/E1D and 8231-E2C/E2D GX++ Adapters710 4-core710 6-/8-core730 2-proc mod #EJ0G Dual-port 12X Channel Attach (for PCI I/O drawers) n/a Both Slots 1+2 used #EJ0H 2-port PCIe2 x8 (for Ultra SSD Drawer) n/aSlot 1Slot 1 and 2 Note: use QDR Adapter #5283 on “C” models in Gen2 PCIe slot instead of DDR connection through GX adapter “B” models: 8231-E2B GX++ Adapters710 4-core710 6-/8-core730 2-proc mod #5266 Dual-port 4x Channel Attach (for 4x InfiniBand switch) Slot 1 Slot 1 and 2

37 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 37 Adaptadores GX++ Power 730 GX++ (para 8231-E2C/E2D) -- Nota: 8231-E2B não possui funcionalidade 12X loop --  #EJ0G GX++ Dual-port 12x Attach  Provê 12X loop –Suporta até dois PCIe 12X IO Drawers (#5802 e/oo #5877) –PCI-X (#5796) drawers NÃO suportado  Adaptador 12X MAIS 2o adaptador SPCN (ambos cards enviados como um FC#EJ0G) –Adaptadores Double wide encobre ambos slot PCIe LAN C7 e slot PCIe adjacente –Plus SPCN adapter uses GX++ Slot 1  Adaptador #5260/#9056 LAN requerido deve ser movido para outro slot PCIe no servidor (CEC ou I/O drawer) Double-wide card SPCN CARD (single wide)

38 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 38 Slots GX Power 720/740  GX++ Slot 1: –Disponível em 720/740 –Para PCIe Riser card ou adaptador GX++  GX++ Slot 2: –Disponível em 740 com dois processadores –NÃO disponível em 720 ou 740 com um processador –Espaço compartilhado com slot PCIe “C7” LAN –Para adaptadores GX++ Figura mostra 720/740 modelos “C/D”, mas é o mesmo para slots GX modelo “B”

39 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 39 Adaptadores GX++ 720/740: Modelos “D”  O que eu conecto nos slots GX? Usado paraTambém usado para 12X Channel Attach Adapter Conexão 12X I/O drawers #5802/#5877/#5796 (AIX/IBM i/Linux) Conexão para Switch 4X DDR InfiniBand (AIX/Linux) PCIe2 x8 Adapter * Conexão EXP30 Ultra SSD I/O Drawer (#EDR1) (AIX/IBM i/Linux) --- PCIe Riser Card ** PCIe Riser Card (AIX/IBM i/Linux) --- * Disponível somente nos modelos “C/D” ** PCIe Riser Card não é um “adaptador”, mas quando usado não é permitido adaptador GX++ no Slot 1

40 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 40 Adaptadores GX++ 720/740: Modelos “C”  O que eu conecto nos slots GX? Usado paraTambém usado para 12X Channel Attach Adapter Conexão 12X I/O drawers #5802/#5877/#5796 (AIX/IBM i/Linux) Conexão para Switch 4X DDR InfiniBand (AIX/Linux) PCIe2 x8 Adapter * Conexão EXP30 Ultra SSD I/O Drawer (#5888) (AIX/Linux) --- PCIe Riser Card ** PCIe Riser Card (AIX/IBM i/Linux) --- * Disponível somente nos modelos “C/D” ** PCIe Riser Card não é um “adaptador”, mas quando usado não é permitido adaptador GX++ no Slot 1

41 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 41 Adaptadores GX++ 720/740 – Detalhes Modelos “C/D” 8202-E4C/E4D and 8205-E6C/E6D GX++ Adapters* 720 4-core720 6-/8-core740 1-proc mod 740 2-proc mod #EJ04 Dual-port 12X Channel Attach (for PCI I/O drawers) n/a w/ 12X cables Slot 1 w/ 12X cables Slot 1 w/ 12X cables Slot 1 and 2 w/ 12X cables #EJ04 Dual-port 12X Channel Attach (for 4x InfiniBand switch) ** Slot 1 w/ 12X to 4X converter cable Slot 1 w/ 12X to 4X converter cable Slot 1 w/ 12X to 4X converter cable Slot 1 and 2 w/ 12X to 4X converter cable #EJ03 2-port PCIe2 x8 (for Ultra SSD Drawer) n/aSlot 1 Slot 1 and 2 * PCIe Riser Card not really an “adapter”, but when used does not allow a GX++ adapter to be placed in Slot 1 ** Generally recommend QDR Adapter #5285/5283 on “C” models in Gen2 PCIe slot instead of DDR connection through GX adapter Modelos “B” 8202-E4B and 8205-E6B GX++ Adapters* 720 4-core720 6-/8-core740 1-proc mod 740 2-proc mod #5615 Dual-port 12X Channel Attach (for PCI I/O drawers) n/a w/ 12X cables Slot 1 w/ 12X cables Slot 1 w/ 12X cables Slot 1 and 2 w/ 12X cables #5615 Dual-port 12X Channel Attach (for 4x InfiniBand switch) Slot 1 w/ 12X to 4X converter cable Slot 1 w/ 12X to 4X converter cable Slot 1 w/ 12X to 4X converter cable Slot 1and 2 w/ 12X to 4X converter cable

42 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 42 #5685 PCIe Riser Card Opcional (720/740) Conecta no slot GX Se usado, não há como conectar outro adaptador GX  4 Slots PCIe opcionais –Low profile, menor –Gen2 para modelos “C/D” –Gen1 ou Gen2 para modelos “B” –Como uma “mini I/O” drawer  Não hot plug  Para 720/740 rack mount

43 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 43 Slots GX++ 750/760 Requer servidores com dois ou mais sockets de processadores  Conexão para adaptadores GX++ –#1808 para 12X-attached I/O Drawers (#5802/5877) –#1914 para Ultra SSD I/O Drawer (#EDR1) –#5285 para 4X QDR IB conectividade/performance para outros servidores  Nenhum Slot GX++ habilitado com apenas um DCM  Dois slots GX++ habilitado com dois ou mais DCM  Não Hot Swap (agende parada para adicionar/remover/reparar) GX++ Bus

44 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 44 Slots GX++ 770/780  Conexão para adaptadores GX++ –#1808 para 12X-attached I/O Drawers (#5802/5877/5796) –#1914 para Ultra SSD I/O Drawer (#EDR1) –#5285 para 4X QDR IB conectividade/performance para outros servidores  Dois slots GX++  Hot-plug GX++ Bus

45 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 45 Power 795 & PCIe Gen2 – Funcionalidades  Conecte adaptador GX++ PCIe diretamente no slot GX++ do processor card  Sem cabeamento exceto fibra ótica para downstream I/O switch  Max 3 adaptadores GX++ PCIe por processor book  Pode ser em qualquer dos 4 slots GX  Usando um adaptador GX++ PCIe significa I/O Drawer não pode ser colocada no slot GX. Pode ter um ou outro. Ok para mixar.  Sem alterações para mínimo de um #5803 I/O drawer por 795

46 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 46  Duas portas – 10 Gb  Cada porta roda Ethernet e/ou Fibre Channel  N_Port ID Virtualization (NPIV) através VIOS  Conexão para switch é suportado (conexão direto a dispositivos não é suportado)  OS levels requerido –AIX 7.1 com TL 7100-02 –AIX 6.1 com TL 6100-08 –IBM i – 6.1 ou superior com VIOS –Linux - RHEL 6.4 –VIOS 2.2.2.0 –Firmware 7.6 requerido  Cabo padrão fibra ótica SR com conectores tipo LC até 300m Adaptador GX++ 2-port 10Gb FCoE (CNA) SR Optical (#EN22) Provê funções de um adaptador PCIe Gen2 CCIN = 2B74  FCoE = Fibre Channel over Ethernet  CNA = Converged Network Adapter  Termos são intercambiáveis  FCoE = Fibre Channel over Ethernet  CNA = Converged Network Adapter  Termos são intercambiáveis

47 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 47  Duas portas – 6 Gb Fibre Channel cada  Link speeds de 4, 8 e 16 Gbps (auto negotiation suportado)  N_Port ID Virtualization (NPIV) através do VIOS  Conexão para switch é suportado (conexão direto a dispositivos não é suportado)  OS levels requerido –AIX 7.1 com TL 7100-02 –AIX 6.1 com TL 6100-08 –IBM i – 6.1 ou superior com VIOS –Linux - RHEL 6.4 –VIOS 2.2.2.0 –Firmware 7.6 requerido  Cabo padrão fibra ótica SR com conectores tipo LC Adaptador GX++ 2-port 16Gb Fibre Channel (#EN23) Provê funções de um adaptador PCIe Gen2 CCIN = 2B9B 1 o Fibre Channel 16 Gb para Power Systems

48 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 48 Sumário da Unidade Você deverá estar apto a discutir os seguintes itens:  Identificar I/O que estão próximos do end-of-life  Identificar os vários I/O drawers suportados por servidores POWER7  Discutir o suporte Power Systems para loops12X e adaptadores GX entre as linhas de produto  Guiar as considerações de I/O de seus clientes durante aquisição, atualização e cenários de planejamento de migrações

49 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 49 This document was developed for IBM offerings in the United States as of the date of publication. IBM may not make these offerings available in other countries, and the information is subject to change without notice. Consult your local IBM business contact for information on the IBM offerings available in your area. Information in this document concerning non-IBM products was obtained from the suppliers of these products or other public sources. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give you any license to these patents. Send license inquires, in writing, to IBM Director of Licensing, IBM Corporation, New Castle Drive, Armonk, NY 10504-1785 USA. All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. The information contained in this document has not been submitted to any formal IBM test and is provided "AS IS" with no warranties or guarantees either expressed or implied. All examples cited or described in this document are presented as illustrations of the manner in which some IBM products can be used and the results that may be achieved. Actual environmental costs and performance characteristics will vary depending on individual client configurations and conditions. IBM Global Financing offerings are provided through IBM Credit Corporation in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates are based on a client's credit rating, financing terms, offering type, equipment type and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without notice. IBM is not responsible for printing errors in this document that result in pricing or information inaccuracies. All prices shown are IBM's United States suggested list prices and are subject to change without notice; reseller prices may vary. IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply. Any performance data contained in this document was determined in a controlled environment. Actual results may vary significantly and are dependent on many factors including system hardware configuration and software design and configuration. Some measurements quoted in this document may have been made on development-level systems. There is no guarantee these measurements will be the same on generally-available systems. Some measurements quoted in this document may have been estimated through extrapolation. Users of this document should verify the applicable data for their specific environment. Special Notices

50 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 50 IBM, the IBM logo, ibm.com, AIX, AIX (logo), AIX 5L, AIX 6 (logo), AS/400, Active Memory, BladeCenter, Blue Gene, Chiphopper, DB2, DB2 Universal Database, DS4000, DS6000, DS8000, EnergyScale, Enterprise Workload Manager, ESCON, GPFS, HACMP, HACMP/6000, i5/OS, i5/OS (logo), IBM Business Partner (logo), IBM Systems Director Active Energy Manager, IntelliStation, iSeries, LoadLeveler, Lotus, Lotus Notes, Micro- Partitioning, Notes, Operating System/400, OS/400, PartnerLink, PartnerWorld, POWER, Power Architecture, Power Everywhere, Power Family, POWER Hypervisor, Power Systems, Power Systems (logo), Power Systems Software, Power Systems Software (logo), POWER2, POWER3, POWER4, POWER4+, POWER5, POWER5+, POWER6, POWER7, PowerExecutive, PowerHA, PowerPC, PowerVM, PowerVM (logo), pSeries, pureScale, Rational, RISC System/6000, RS/6000, System i, System p, System p5, System Storage, System z, THINK, Tivoli, Tivoli (logo), Tivoli Enterprise Console, WebSphere, Workload Partitions Manager, X-Architecture, xSeries, z/OS and zSeries are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. If these and other IBM trademarked terms are marked on their first occurrence in this information with a trademark symbol (® or ™), these symbols indicate U.S. registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries. AltiVec is a trademark of Freescale Semiconductor, Inc. AMD Opteron is a trademark of Advanced Micro Devices, Inc. InfiniBand, InfiniBand Trade Association and the InfiniBand design marks are trademarks and/or service marks of the InfiniBand Trade Association. Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency which is now part of the Office of Government Commerce. Java and all Java-based trademarks and logos are trademarks or registered trademarks of Oracle and/or its affiliates. Linear Tape-Open, LTO, the LTO Logo, Ultrium, and the Ultrium logo are trademarks of HP, IBM Corp. and Quantum in the U.S. and other countries. Linux is a registered trademark of Linus Torvalds in the United States, other countries or both. Microsoft, Windows and the Windows logo are registered trademarks of Microsoft Corporation in the United States, other countries or both. NetBench is a registered trademark of Ziff Davis Media in the United States, other countries or both. SPECint, SPECfp, SPECjbb, SPECweb, SPECjAppServer, SPEC OMP, SPECviewperf, SPECapc, SPEChpc, SPECjvm, SPECmail, SPECimap and SPECsfs are trademarks of the Standard Performance Evaluation Corp (SPEC). The Power Architecture and Power.org wordmarks and the Power and Power.org logos and related marks are trademarks and service marks licensed by Power.org. TPC-C and TPC-H are trademarks of the Transaction Performance Processing Council (TPPC). UNIX is a registered trademark of The Open Group in the United States, other countries or both. Other company, product and service names may be trademarks or service marks of others. Special Notices (cont.)

51 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 51 Notes on Performance Estimates rPerf for AIX rPerf (Relative Performance) is an estimate of commercial processing performance relative to other IBM UNIX systems. It is derived from an IBM analytical model which uses characteristics from IBM internal workloads, TPC and SPEC benchmarks. The rPerf model is not intended to represent any specific public benchmark results and should not be reasonably used in that way. The model simulates some of the system operations such as CPU, cache and memory. However, the model does not simulate disk or network I/O operations. rPerf estimates are calculated based on systems with the latest levels of AIX and other pertinent software at the time of system announcement. Actual performance will vary based on application and configuration specifics. The IBM eServer pSeries 640 is the baseline reference system and has a value of 1.0. Although rPerf may be used to approximate relative IBM UNIX commercial processing performance, actual system performance may vary and is dependent upon many factors including system hardware configuration and software design and configuration. Note that the rPerf methodology used for the POWER6 systems is identical to that used for the POWER5 systems. Variations in incremental system performance may be observed in commercial workloads due to changes in the underlying system architecture. All performance estimates are provided "AS IS" and no warranties or guarantees are expressed or implied by IBM. Buyers should consult other sources of information, including system benchmarks, and application sizing guides to evaluate the performance of a system they are considering buying. For additional information about rPerf, contact your local IBM office or IBM authorized reseller. ======================================================================== CPW for IBM i Commercial Processing Workload (CPW) is a relative measure of performance of processors running the IBM i operating system. Performance in customer environments may vary. The value is based on maximum configurations. More performance information is available in the Performance Capabilities Reference at: www.ibm.com/systems/i/solutions/perfmgmt/resource.htmlwww.ibm.com/systems/i/solutions/perfmgmt/resource.html

52 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 52 The IBM benchmarks results shown herein were derived using particular, well configured, development-level and generally-available computer systems. Buyers should consult other sources of information to evaluate the performance of systems they are considering buying and should consider conducting application oriented testing. For additional information about the benchmarks, values and systems tested, contact your local IBM office or IBM authorized reseller or access the Web site of the benchmark consortium or benchmark vendor. IBM benchmark results can be found in the IBM Power Systems Performance Report at http://www.ibm.com/systems/p/hardware/system_perf.html.http://www.ibm.com/systems/p/hardware/system_perf.html All performance measurements were made with systems running the AIX operating system unless otherwise indicated to have used Linux. For new and upgraded systems, AIX Version 4.3, AIX 5 or AIX 6 were used. All other systems used previous versions of AIX. The SPEC CPU2006 and SPEC CPU2000 benchmarks were compiled using IBM's high performance C, C++, and FORTRAN compilers for AIX and Linux. For new and upgraded systems, the latest versions of these compilers were used: XL C for AIX v11.1, XL C/C++ for AIX v11.1, XL FORTRAN for AIX v13.1, XL C/C++ for Linux v11.1, and XL FORTRAN for Linux v13.1. For a definition/explanation of each benchmark and the full list of detailed results, visit the Web site of the benchmark consortium or benchmark vendor. TPChttp://www.tpc.orghttp://www.tpc.org SPEChttp://www.spec.orghttp://www.spec.org LINPACKhttp://www.netlib.org/benchmark/performance.pdfhttp://www.netlib.org/benchmark/performance.pdf PTC Creo (formerly Pro/E)http://www.ptc.com/products/creo/http://www.ptc.com/products/creo/ GPC http://www.spec.org/gwpg/http://www.spec.org/gwpg/ VolanoMark http://www.volano.comhttp://www.volano.com STREAMhttp://www.cs.virginia.edu/stream/http://www.cs.virginia.edu/stream/ SAP http://www.sap.com/solutions/benchmark/index.epxhttp://www.sap.com/solutions/benchmark/index.epx Oracle Applicationshttp://www.oracle.com/us/solutions/benchmark/apps-benchmark/index-166919.htmlhttp://www.oracle.com/us/solutions/benchmark/apps-benchmark/index-166919.html ANSYS FLUENThttp://www.ansys.com/Support/Platform+Support/Benchmarks+Overviewhttp://www.ansys.com/Support/Platform+Support/Benchmarks+Overview TOP500 Supercomputershttp://www.top500.org/http://www.top500.org/ Ideas Internationalhttp://www.ideasinternational.com/Free-Advisory/Benchmark-Gatewayhttp://www.ideasinternational.com/Free-Advisory/Benchmark-Gateway Storage Performance Councilhttp://www.storageperformance.org/resultshttp://www.storageperformance.org/results Notes on Benchmarks and Values

53 © 2013 IBM Corporation IBM Power Systems This document is for IBM and IBM Business Partner use only. It is not intended for client distribution or use with clients 53 Notes on HPC Benchmarks and Values The IBM benchmarks results shown herein were derived using particular, well configured, development-level and generally-available computer systems. Buyers should consult other sources of information to evaluate the performance of systems they are considering buying and should consider conducting application oriented testing. For additional information about the benchmarks, values and systems tested, contact your local IBM office or IBM authorized reseller or access the Web site of the benchmark consortium or benchmark vendor. IBM benchmark results can be found in the IBM Power Systems Performance Report at http://www.ibm.com/systems/p/hardware/system_perf.html.http://www.ibm.com/systems/p/hardware/system_perf.html All performance measurements were made with systems running AIX or AIX 5L operating systems unless otherwise indicated to have used Linux. For new and upgraded systems, the latest versions of AIX were used. All other systems used previous versions of AIX. The LINPACK, and Technical Computing benchmarks were compiled using IBM's high performance C, C++, and FORTRAN compilers for AIX and Linux. For new and upgraded systems, the latest versions of these compilers were used: XL C for AIX V11.1, XL C/C++ for AIX V11.1, XL FORTRAN for AIX V13.1, XL C/C++ for Linux V11.1, and XL FORTRAN for Linux V13.1. Linpack HPC (Highly Parallel Computing) used the current versions of the IBM Engineering and Scientific Subroutine Library (ESSL). For Power7 systems, IBM Engineering and Scientific Subroutine Library (ESSL) for AIX Version 5.1 and IBM Engineering and Scientific Subroutine Library (ESSL) for Linux Version 5.1 were used. For a definition/explanation of each benchmark and the full list of detailed results, visit the Web site of the benchmark consortium or benchmark vendor. SPEChttp://www.spec.orghttp://www.spec.org LINPACKhttp://www.netlib.org/benchmark/performance.pdfhttp://www.netlib.org/benchmark/performance.pdf PTC Creo (formerly Pro/E)http://www.ptc.com/products/creo/http://www.ptc.com/products/creo/ GPC http://www.spec.org/gwpg/http://www.spec.org/gwpg/ STREAMhttp://www.cs.virginia.edu/stream/http://www.cs.virginia.edu/stream/ TOP500 Supercomputershttp://www.top500.org/http://www.top500.org/ AMBERhttp://ambermd.org/http://ambermd.org/ GAMESShttp://www.msg.chem.iastate.edu/gamesshttp://www.msg.chem.iastate.edu/gamess GAUSSIANhttp://www.gaussian.comhttp://www.gaussian.com ANSYS FLUENThttp://www.ansys.com/services/hardware-support-db.htmhttp://www.ansys.com/services/hardware-support-db.htm ABAQUShttp://www.simulia.com/support/v68/v68_performance.phphttp://www.simulia.com/support/v68/v68_performance.php ECLIPSEhttp://www.sis.slb.com/content/software/simulation/index.asp?seg=geoquest&http://www.sis.slb.com/content/software/simulation/index.asp?seg=geoquest& MM5http://www.mmm.ucar.edu/mm5/http://www.mmm.ucar.edu/mm5/ MSC.NASTRANhttp://www.mscsoftware.com/support/prod%5Fsupport/nastran/performance/v04_sngl.cfmhttp://www.mscsoftware.com/support/prod%5Fsupport/nastran/performance/v04_sngl.cfm STAR-CDhttp://www.cd-adapco.com/products/star_cd/performance/406/index.htmlhttp://www.cd-adapco.com/products/star_cd/performance/406/index.html NAMDhttp://www.ks.uiuc.edu/Research/namdhttp://www.ks.uiuc.edu/Research/namd HMMERhttp://hmmer.janelia.org/http://hmmer.janelia.org/ http://powerdev.osuosl.org/project/hmmerAltivecGen2mod


Carregar ppt "© 2013 IBM Corporation Follow us Learn more at This document is for IBM and IBM Business."